1998
DOI: 10.1002/(sici)1097-4636(19980905)41:3<481::aid-jbm19>3.0.co;2-l
|View full text |Cite
|
Sign up to set email alerts
|

In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: Muscle and perineural tissue responses and encapsule membrane thickness

Abstract: Nickel-titanium shape memory alloy (Nitinol) has properties that could be very useful in surgical applications. Thermal shape memory, superelasticity, and high damping properties make such alloys behave differently compared to other implant metals. There has previously been a lack of sufficient evidence on the biocompatibility of Nitinol. The purpose of this study was to evaluate general soft tissue response and biocompatibility to Nitinol in vivo, and to clarify neural and perineural responses, previously unr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
54
0
1

Year Published

1999
1999
2013
2013

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 167 publications
(59 citation statements)
references
References 38 publications
4
54
0
1
Order By: Relevance
“…Copper and silver are unacceptable as stimulating electrodes, as these metals cause tissue necrosis even in the absence of current (Fisher et al, 1961;Dymond et al, 1970;Sawyer and Srinivasan, 1974;Stensaas and Stensaas, 1978;Babb and Kupfer, 1984). Nickel-titanium shape memory alloys have good biocompatibility response (Ryhanen et al, 1998), up to a nickel content of 50% (Bogdanski et al, 2002).…”
Section: Materials Used As Electrodes For Charge Injection and Reversmentioning
confidence: 54%
“…Copper and silver are unacceptable as stimulating electrodes, as these metals cause tissue necrosis even in the absence of current (Fisher et al, 1961;Dymond et al, 1970;Sawyer and Srinivasan, 1974;Stensaas and Stensaas, 1978;Babb and Kupfer, 1984). Nickel-titanium shape memory alloys have good biocompatibility response (Ryhanen et al, 1998), up to a nickel content of 50% (Bogdanski et al, 2002).…”
Section: Materials Used As Electrodes For Charge Injection and Reversmentioning
confidence: 54%
“…Recently, porous Ni-Ti inter-metallics alloys have received increasing attention as potential materials for porous orthopaedic implants, due to their good corrosion resistance and unique mechanical properties [64,82,135,136]. Ni-Ti is comparable to 316L stainless steel, in that both share the presence of an adherent TiO 2 surface oxide, which in the case of Ni-Ti prevents nickel dissolution and release [137].…”
Section: Characteristics Of Porous Metals That Affect Their Performancementioning
confidence: 99%
“…(4) Good corrosion resistance and biocompatibility: many in vitro and in vivo studies [7][8][9][10] indicate that TiNi alloy has extremely good corrosion resistance and biocompatibility, mainly due to the formation of a passive dense titanium-oxide layer (TiO 2 ).…”
Section: Introductionmentioning
confidence: 99%