In vitro uptake and elimination of isoflurane by different membrane oxygenators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
9
0
7

Year Published

1998
1998
2019
2019

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 9 publications
0
9
0
7
Order By: Relevance
“…Notwithstanding the variances in delivery of isoflurane to the oxygenator, uptake by the patient can be affected by the design of oxygenator as they have different gas transfer characteristics. 25 As we used the same design of oxygenator in all patients, this will not have been a source of variance in our findings but limits extrapolation of our findings to different designs of oxygenators. However, subsequent research by our group found no difference in arterial blood concentrations of isoflurane between the one used in the present study and a different design of polypropylene oxygenator.…”
Section: Discussionmentioning
confidence: 95%
“…Notwithstanding the variances in delivery of isoflurane to the oxygenator, uptake by the patient can be affected by the design of oxygenator as they have different gas transfer characteristics. 25 As we used the same design of oxygenator in all patients, this will not have been a source of variance in our findings but limits extrapolation of our findings to different designs of oxygenators. However, subsequent research by our group found no difference in arterial blood concentrations of isoflurane between the one used in the present study and a different design of polypropylene oxygenator.…”
Section: Discussionmentioning
confidence: 95%
“…Another factor that might account for the differences in findings between the studies was the type of oxygenator that was used as an in-vitro study by Hickey and colleagues has found that different designs have different transfer rates for anaesthetic gases to exchange into the blood circulation. 19 As no studies have been undertaken in humans to compare the gas transfer of isoflurane between different oxygenators, the importance of this in the relationship between arterial and oxygenator exhaust isoflurane concentration is unknown. We are currently undertaking a study (NCT03146949) to determine whether there are any differences in blood concentrations of isoflurane between different makes of oxygenators.…”
Section: Discussionmentioning
confidence: 99%
“…The permeability of the different oxygenators to volatile anesthetics have been the subject of numerous studies (1720). In these studies, the volatile anesthetic was supplied during a defined time interval using the fresh gas supply to the oxygenators.…”
Section: Discussionmentioning
confidence: 99%