2022
DOI: 10.1016/j.toxrep.2022.05.004
|View full text |Cite
|
Sign up to set email alerts
|

In vitro toxicogenomic activity of an MTA/salicylate-based endodontic sealer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 39 publications
(48 reference statements)
0
2
0
Order By: Relevance
“…Regarding the number of cells evaluated in the micronucleus assay, a total of five studies evaluated 1,000 cells per slide. For the alkaline comet assay, a total of three studies evaluated 100 randomly selected comets per slide, totaling 300 comets ( Teixeira et al, 2021 , Baraba et al, 2011 , Dhopavkar et al, 2021 ), whereas 50 comets per treatment were evaluated in four studies ( Leme and Salvadori, 2022 , Huang et al, 2002 , Huang et al, 2004 , Dhopavkar et al, 2021 ). The study conducted by Nair et al (2018) evaluated from 50 to 100 cells per sample, whereas the study by Camargo et al (2014) evaluated only 25 cells and three studies failed to inform the amount of analyzed cells.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Regarding the number of cells evaluated in the micronucleus assay, a total of five studies evaluated 1,000 cells per slide. For the alkaline comet assay, a total of three studies evaluated 100 randomly selected comets per slide, totaling 300 comets ( Teixeira et al, 2021 , Baraba et al, 2011 , Dhopavkar et al, 2021 ), whereas 50 comets per treatment were evaluated in four studies ( Leme and Salvadori, 2022 , Huang et al, 2002 , Huang et al, 2004 , Dhopavkar et al, 2021 ). The study conducted by Nair et al (2018) evaluated from 50 to 100 cells per sample, whereas the study by Camargo et al (2014) evaluated only 25 cells and three studies failed to inform the amount of analyzed cells.…”
Section: Resultsmentioning
confidence: 99%
“…Regarding the comet assay, the use of software programs was the basis of some parameters analysis. While Teixeira et al (2021) and Leme and Salvadori (2022) evaluated tail intensity and Nair et al (2018) only evaluated tail moment, all the other comet assay studies evaluated tail intensity and tail moment. As for the c-H2AX immunofluorescence assay studies, cell count and standardized foci quantification were considered.…”
Section: Resultsmentioning