1997
DOI: 10.1016/s0109-5641(97)80016-4
|View full text |Cite
|
Sign up to set email alerts
|

In vitro toothbrush-dentifrice abrasion of resin-modified glass ionomers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
40
0
23

Year Published

2003
2003
2017
2017

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(65 citation statements)
references
References 11 publications
2
40
0
23
Order By: Relevance
“…Specimens were maintained in 100% relative humidity at 37°C for 20 min (7,8) and embedded in acrylic resin (Varidur; High Performance Mounting Kit; Buehler, Lake Bluff, IL, USA) to facilitate mounting in the testing devices. Specimen surfaces were wet-polished using a sequence of 500, 1,200, 2,400, and 4,000 grit silicon carbide paper (9), then immersed in distilled water at 37°C for 24 h (6,(8)(9)(10).…”
Section: Specimen Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Specimens were maintained in 100% relative humidity at 37°C for 20 min (7,8) and embedded in acrylic resin (Varidur; High Performance Mounting Kit; Buehler, Lake Bluff, IL, USA) to facilitate mounting in the testing devices. Specimen surfaces were wet-polished using a sequence of 500, 1,200, 2,400, and 4,000 grit silicon carbide paper (9), then immersed in distilled water at 37°C for 24 h (6,(8)(9)(10).…”
Section: Specimen Preparationmentioning
confidence: 99%
“…Next, each specimen was mounted on a custom-made toothbrushing machine and brushed using a straight, soft toothbrush (Oral-B 40, Procter & Gamble, Cincinnati, OH, USA) with a load of 1.96 N (14-16) at a speed of 175 cycles/min for 20,000 double strokes (7,17,18). This is reported to simulate roughly 2 years of brushing (18).…”
Section: Toothbrushing Abrasion Testmentioning
confidence: 99%
“…Thus, the latter is more susceptible to degradation. 27 Turker and Biskin 10 in 2002 reported an increase in microhardness of GICs after bleaching and attributed this increase to accumulation of silica cores on the GIC surface after bleaching and erosion of cement and movement of indenter of Vickers hardness tester on these cores. The results of the current study showed no significant difference in microhardness among the laser-bleached subgroups of each of the conventional and resin modified GICs.…”
Section: Discussionmentioning
confidence: 99%
“…To exemplify, Mair et al 5 , Yap et al 6 , Condon & Ferracani 7 , and Momoi et al 8 used devices that reproduce the wear of composite resins in a complex interaction of the mechanisms of erosion, corrosion, adhesion, abrasion and impact. Deterioration can also be accelerated through mechanical fatigue.…”
Section: Introductionmentioning
confidence: 99%