2018
DOI: 10.1016/j.jvs.2017.03.442
|View full text |Cite
|
Sign up to set email alerts
|

In vitro particulate and in vivo drug retention study of a novel polyethylene oxide formulation for drug-coated balloons

Abstract: The amorphous PAT in the PEO balloon provided comparable drug tissue retention levels to those of the commercially available DCB and fewer particulates. Thus prepared PEO balloon proved to be safe and effective in the preclinical experimental setting. The clinical outcomes of these findings need further investigation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
16
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(20 citation statements)
references
References 28 publications
(24 reference statements)
4
16
0
Order By: Relevance
“…The PAT powder demonstrated an endothermic peak at 221°C, indicating a crystalline nature for the PAT powder. Importantly, this peak does not exist for Balloons 4, 11, 16, or 22, indicating that PAT is in the amorphous form in the balloon coatings (Figure 8a) as previously reported (Anderson et al, ; Anderson et al, ).…”
Section: Resultssupporting
confidence: 79%
“…The PAT powder demonstrated an endothermic peak at 221°C, indicating a crystalline nature for the PAT powder. Importantly, this peak does not exist for Balloons 4, 11, 16, or 22, indicating that PAT is in the amorphous form in the balloon coatings (Figure 8a) as previously reported (Anderson et al, ; Anderson et al, ).…”
Section: Resultssupporting
confidence: 79%
“…7 The PEO-based DCB has been shown to be safe and effective through minimal particulates shed and therapeutic amounts of drug retained in the tissues at day 30, respectively. 8 This demonstrates its potential as an alternative to the currently available DCBs to treat a single lesion.…”
mentioning
confidence: 88%
“…The methods of the model are provided in our previous study. 8 The particulates were imaged using an Olympus SZX10 stereo microscope equipped with Olympus DP22 camera (Olympus America, Center Valley, Pa), and the number of particulates and average size of the particulates were quantitatively analyzed (>100 mm) using ImageJ software (National Institutes of Health, Bethesda, Md). For proper visualization, the white particulates were artificially colored green.…”
Section: Characterization Of Mr-tmd-dcbsmentioning
confidence: 99%
See 2 more Smart Citations