2013
DOI: 10.1016/j.athoracsur.2012.11.039
|View full text |Cite
|
Sign up to set email alerts
|

In Vitro Mitral Valve Simulator Mimics Systolic Valvular Function of Chronic Ischemic Mitral Regurgitation Ovine Model

Abstract: Background This study was undertaken to evaluate an in vitro mitral valve simulator's ability to mimic the systolic leaflet coaptation, regurgitation, and leaflet mechanics of a healthy and chronic ischemic mitral regurgitation (IMR) ovine model. Methods Mitral valve size and geometry of both healthy and chronic IMR ovine animals was used to recreate systolic mitral valve function in vitro. A2-P2 coaptation length, coaptation depth, tenting area, anterior leaflet strain, and mitral regurgitation were compare… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
44
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
4
3

Relationship

4
3

Authors

Journals

citations
Cited by 32 publications
(48 citation statements)
references
References 26 publications
(46 reference statements)
4
44
0
Order By: Relevance
“…To date, published studies have primarily focused on functional diseases that include ischemic and non-ischemic dilated cardiomyopathies. 8,28,29,34,35,37,46,47 In functional disease, left ventricular remodeling distends the MV geometry by dilating the MV annulus and displacing the PMs away from the mitral leaflets. These geometric distortions restrict systolic leaflet motion, generate gaps between the closed leaflets, and lead to MR.…”
Section: Summary Of Efforts To Create Disease Modelsmentioning
confidence: 99%
See 3 more Smart Citations
“…To date, published studies have primarily focused on functional diseases that include ischemic and non-ischemic dilated cardiomyopathies. 8,28,29,34,35,37,46,47 In functional disease, left ventricular remodeling distends the MV geometry by dilating the MV annulus and displacing the PMs away from the mitral leaflets. These geometric distortions restrict systolic leaflet motion, generate gaps between the closed leaflets, and lead to MR.…”
Section: Summary Of Efforts To Create Disease Modelsmentioning
confidence: 99%
“…While the majority of annuluses reported in literature provide only a single size, adjustable and flexible annuluses have been reported. 22,29,37,46,47 These designs are described and evaluated in subsequent sections evaluating methods of assessing MV annuloplasty.…”
Section: Selectionmentioning
confidence: 99%
See 2 more Smart Citations
“…A novel closed-loop left heart simulator ( Fig. 1) was utilized to carry out controlled in-vitro MV experiments [7,8]. It allows for precise control of annular and subvalvular MV geometry at physiological left heart hemodynamics.…”
Section: Methodsmentioning
confidence: 99%