2003
DOI: 10.1016/j.prosdent.2003.09.020
|View full text |Cite
|
Sign up to set email alerts
|

In vitro deformation of acetyl resin and metal alloy removable partial denture direct retainers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
25
2

Year Published

2008
2008
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(30 citation statements)
references
References 6 publications
0
25
2
Order By: Relevance
“…In the present study, we investigated the clinical application of thermoplastic resins with emphasis on the esthetic aspects relative to conventional denture resins. Black tea, green tea and red wine were considered as soaking solutions, but coffee and curry were selected because of their stainability and amount of consumption by the public [28][29][30][31][32][33][34][35] . L*, a*, and b* indicate lightness, red-green, and yellow-blue, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, we investigated the clinical application of thermoplastic resins with emphasis on the esthetic aspects relative to conventional denture resins. Black tea, green tea and red wine were considered as soaking solutions, but coffee and curry were selected because of their stainability and amount of consumption by the public [28][29][30][31][32][33][34][35] . L*, a*, and b* indicate lightness, red-green, and yellow-blue, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…An attempt to improve the aesthetic effect by the reduction of RCA ends up with weakening of the retention force of RPD 15 . Retentive clasp arms of RPD are one of the factors that dictate the durability and function benefits of dentures 16 . It has been found that the durability of RCA depends on the material used as well as its design 17,18 .…”
Section: Introductionmentioning
confidence: 99%
“…The photogrammetric procedure for measuring the two‐dimensional damage area was based on high‐resolution digital images with a standard reference scale for image calibration and open‐source software for image processing. Similar procedures have been successfully applied in the assessment of dental prostheses with curved surfaces and eroded metallurgical samples 28, 29. The defined measurement criteria for the surface features and damage modes (Table III) aided repeatability among different observers, which is especially important for uniform detection and identification of damage boundaries during image segmentation.…”
Section: Discussionmentioning
confidence: 99%