2011
DOI: 10.1016/j.chroma.2010.12.055
|View full text |Cite
|
Sign up to set email alerts
|

In vitro cytochrome P450 activity: Development and validation of a sensitive high performance liquid chromatography–tandem mass spectrometry method for the quantification of six probe metabolites after derivatization with pyridine-3-sulfonyl chloride in an aqueous environment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…This saved sample preparation as well as time compared with other methods (Testino and Patonay, ; Bhoopathy et al ., ; Li et al ., ; De Bock et al ., ). Compared with other systems, this system used 200 μL of 0.5 mg/mL microsome protein for each run (Testino and Patonay, ; Atkinson et al ., ; De Bock et al ., ). Comparing with reported cocktail methods where validation was not fully rounded (Testino and Patonay, ; Kim et al ., ; Otten et al ., ), our method was validated in various aspects, including matrix effects, linearity, LLOQ, accuracy, precision and stability, which sufficiently supported its efficacy.…”
Section: Resultsmentioning
confidence: 99%
“…This saved sample preparation as well as time compared with other methods (Testino and Patonay, ; Bhoopathy et al ., ; Li et al ., ; De Bock et al ., ). Compared with other systems, this system used 200 μL of 0.5 mg/mL microsome protein for each run (Testino and Patonay, ; Atkinson et al ., ; De Bock et al ., ). Comparing with reported cocktail methods where validation was not fully rounded (Testino and Patonay, ; Kim et al ., ; Otten et al ., ), our method was validated in various aspects, including matrix effects, linearity, LLOQ, accuracy, precision and stability, which sufficiently supported its efficacy.…”
Section: Resultsmentioning
confidence: 99%
“…All metabolites were eluted within 7 min and separated in their individual MRM channels. This saved time compared with previously published methods (De Bock et al ., ; Dixit et al ., ; Yin et al ., ).…”
Section: Resultsmentioning
confidence: 99%
“…A large volume of organic solvent is typically used, which dilutes the sample (Otten et al ., ), affects the peak shape of acetaminophen and decreases the sensitivity of metabolites. By using a small volume of stop reagent (25 μL in 250 μL incubation volume; De Bock et al ., ), sample handling was minimized and dilution of the resulting extract was avoided, which increased the sensitivity of the detection.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations