2011
DOI: 10.1155/2011/482485
|View full text |Cite
|
Sign up to set email alerts
|

In Vitro Corrosion Behavior of Lingual Orthodontic Archwires

Abstract: Objectives. To investigate the in vitro electrochemical corrosive behavior of archwires used in lingual orthodontics and the effects on the phase transition temperatures.Materials and Methods. Six different types of archwires of stainless steel, titanium-molybdenum, nickel-titanium and nickel-titanium-copper were used. Corrosion tests were performed following ISO-standard 10993-15:2000. Differential scanning calorimetry and scanning electron microscopy were used.Results. The stainless steel archwires showed an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
10
1
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 39 publications
1
10
1
1
Order By: Relevance
“…and Kim and Johnson. [ 2 15 ] They concluded that the titanium wires appear to be the most inert wire of those tested and are unlikely to release metal ions when used intraorally. They also stated that nitride coating did not affect the corrosion of the alloy.…”
Section: Discussionmentioning
confidence: 99%
“…and Kim and Johnson. [ 2 15 ] They concluded that the titanium wires appear to be the most inert wire of those tested and are unlikely to release metal ions when used intraorally. They also stated that nitride coating did not affect the corrosion of the alloy.…”
Section: Discussionmentioning
confidence: 99%
“…Although it has also been hypothesized that probiotic supplements have a bigger influence on stainless steel than on NiTi the opposite was found. Research to date has suggested that the occurrence of pitting corrosion and localised corrosion is more expressed in stainless steel than in NiTi alloy [36,37]. It is considered that titanium alloy, due to the formation of a passive TiO 2 film on the surface of the archwire, have a greater corrosion resistance than stainless steel, on which a passive Cr 2 O 3 film is formed [38].…”
Section: Roughnessmentioning
confidence: 99%
“…The use of prebrushing rinses, on the other hand, recently indicated no differences in impact on either gingival health or plaque accumulation (7). The surface changes such as discoloration and pitting are considered as main evident of corroding of the stainless steel wire (8)(9)(10)(11) . The current study was undertaken to assess the effect of both chlorhexidine and Listerine on the corrosion resistance of stainless steel wires.…”
Section: Introductionmentioning