In‐stent restenotic lesions can rupture—A case against plaque sealing

Abstract: We present a case of plaque rupture located inside a restenotic stent. Intravascular ultrasound defined a lesion with a minimal lumen area (MLA) of 3.59 cm², plaque burden of 72%, and reference vessel luminal diameter of 4.0 mm with an external elastic membrane lumen cross-section area of 12.6 mm². There was a clearly identified plaque rupture, with a flap-like dissection within the stented segment. Virtual histology intravascular ultrasound confirmed that the adjacent plaque had necrotic core with a thin over… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2011
2011
2017
2017

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 18 publications
0
1
0
1
Order By: Relevance
“…Plaque progression and rupture leading to myocardial infarction (MI) have been reported in rare case reports involving BMS 28,29 and more recently DES. 30 The underlying pathological mechanisms are one of necrotic core plaque progression and rupture either within the stent with BMS or at the stent edge in incompletely covered lipid-core plaque with DES (see Implantation Factors).…”
Section: Progression Of Atherosclerosis Within a Stented Segmentmentioning
confidence: 99%
“…Plaque progression and rupture leading to myocardial infarction (MI) have been reported in rare case reports involving BMS 28,29 and more recently DES. 30 The underlying pathological mechanisms are one of necrotic core plaque progression and rupture either within the stent with BMS or at the stent edge in incompletely covered lipid-core plaque with DES (see Implantation Factors).…”
Section: Progression Of Atherosclerosis Within a Stented Segmentmentioning
confidence: 99%
“…Так в одном из клинических случаев на ВСУЗИ с градациями серого была показана кальцифициро-ванная неоинтима через 8 лет после имплантации стента [29]. В других статьях описан разрыв бляшки и клапаннообразная диссекция внутри рестенозирован-ного стента [30,31]. Кроме того, с помощью ВСУЗИ с ВГ обнаружена неонтимальная гиперплазия с нестабиль-ной морфологией, которая схожа по своим свойствам с фиброатеромой с тонкой капсулой.…”
Section: внутрисосудистое ультразвуковое исследование и виртуальная гunclassified