2014
DOI: 10.1007/s00604-014-1344-0
|View full text |Cite
|
Sign up to set email alerts
|

In-situ synthesis of silver nanoparticles on resin microspheres composed of poly(m-aminophenol), and their application in an enzymatic glucose biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…Typical sensor characteristics in terms of sensitivity, detection limit and Michaelis-Menten rate constant values obtained in this work using both electrochemical and colourimetric methods are compared with various other enzyme based materials reported in literature as shown in Table 1. 28,29,36,[44][45][46][47][48][49][50][51][52][53][54][55][56] It can be seen from the table that GOx-FL Au NPs exhibit a higher sensitivity, lower detection limit and apparently lower K M values for electrochemical detection of glucose when compared to many other electrode materials reported for enzymatic detection of glucose. Similarly in the case of colourimetric detection method using ABTS bio-assay GOx stabilized FL Au NPs display a lower detection limit compared to other materials.…”
Section: Glucose Sensing Using Colourimetric Methodsmentioning
confidence: 99%
“…Typical sensor characteristics in terms of sensitivity, detection limit and Michaelis-Menten rate constant values obtained in this work using both electrochemical and colourimetric methods are compared with various other enzyme based materials reported in literature as shown in Table 1. 28,29,36,[44][45][46][47][48][49][50][51][52][53][54][55][56] It can be seen from the table that GOx-FL Au NPs exhibit a higher sensitivity, lower detection limit and apparently lower K M values for electrochemical detection of glucose when compared to many other electrode materials reported for enzymatic detection of glucose. Similarly in the case of colourimetric detection method using ABTS bio-assay GOx stabilized FL Au NPs display a lower detection limit compared to other materials.…”
Section: Glucose Sensing Using Colourimetric Methodsmentioning
confidence: 99%
“…Aer the immobilization of Ag nanoparticles, a peak appeared near 475 nm due to the surface plasmon resonance of the Ag nanoparticles. 43,44 The blue shi in this peak from 475 nm to 438 nm and 440 nm demonstrates that the Raman reporters and antibodies were modied successfully on the PDA@Ag-NPs. 45,46 Fig.…”
Section: Resultsmentioning
confidence: 91%
“…Glucose is one of the primary energy sources for plants and animals [ 343 ]. In humans, it is found in the blood stream and its levels are related to diabetes mellitus, which is a significant threat to human health [ 344 ].…”
Section: Application Of Enzyme-nanoparticle-polymer Composites In Bio...mentioning
confidence: 99%