2021
DOI: 10.1002/adem.202100159
|View full text |Cite
|
Sign up to set email alerts
|

In Situ Synchrotron X‐Ray Diffraction during High‐Pressure Torsion Deformation of Ni and NiTi

Abstract: p 3 γ torsion , using the van Mises criterion of plastic flow. If there is some outward flow of material between the two anvils and a corresponding reduction in the value of h, it can be taken into account by adding the true (compressive) strain. The size of

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 57 publications
(89 reference statements)
0
4
0
Order By: Relevance
“…Another source of discrepancies between other studies [12][13][14][15][16][17][18][19][20] and ours may be the fact that the ex-situ and in-situ measurements of strength do not combine because of static recrystallization effects that may take place after the ex-situ experiments, i.e. during the unloading event before the ex-situ strength measurements are done [38,39]. Concerning the in-situ experiments such as those reported in [14], the way of torque measurement may be different for different facilities used, i.e.…”
Section: Discussionmentioning
confidence: 62%
“…Another source of discrepancies between other studies [12][13][14][15][16][17][18][19][20] and ours may be the fact that the ex-situ and in-situ measurements of strength do not combine because of static recrystallization effects that may take place after the ex-situ experiments, i.e. during the unloading event before the ex-situ strength measurements are done [38,39]. Concerning the in-situ experiments such as those reported in [14], the way of torque measurement may be different for different facilities used, i.e.…”
Section: Discussionmentioning
confidence: 62%
“…Still, an important result in Ref. 25) was that during pressure release after SPD of Ni at 8 GPa, the crystallite size was increased by more than a factor of 2, and dislocation density was decreased by about a factor of 3, confirming the importance of in situ studies under pressure. Even the application of hydrostatic pressure can significantly increase the dislocation density and reduce the crystallite size, e.g., by a factor of 2 for Zr.…”
Section: Introductionmentioning
confidence: 89%
“…78) They were broadly applied for high-pressure studies in DAC in perpendicular geometry of iron 79) (including PTs), ultrafine-grained metals, 80,81) tantalum at megabar pressure, 82) tungsten carbide, 83) and various geological materials. 8491) Perpendicular diffraction geometry is used by the SPD community during HPT 24,25) (which we discussed in Introduction) and for the high-pressure sliding 92) and compression 93) (Fig. 3(b)).…”
Section: In Situ X-ray Studies With Synchrotron Radiation In Perpendi...mentioning
confidence: 99%
See 1 more Smart Citation