2015
DOI: 10.1039/c5an00474h
|View full text |Cite
|
Sign up to set email alerts
|

In situ nanoparticle sizing with zeptomole sensitivity

Abstract: We present the basis for an entirely new approach to in situ nanoparticle sizing. Nanoparticles containing just 12 zeptomoles (1 zeptomole = 10(-21) moles) of silver, are detected via in situ particle coulometry. These stochastic charge measurements correspond to the transfer of only 7000-8000 electrons, yielding direct information relating to the individual nanoparticle volumes. The resulting particle size distribution (average equivalent radius 5 nm) obtained via nanoparticle coulometry is in excellent corre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
96
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

7
2

Authors

Journals

citations
Cited by 98 publications
(100 citation statements)
references
References 30 publications
(37 reference statements)
0
96
0
Order By: Relevance
“…13 Recently and ‘unrelated at first sight’, a new electrochemical method has emerged 14–16 aiming to unravel electrochemical activity at the single entity level. This electrochemical technique provides the opportunity to characterize single nanoparticles 1719 in situ and large macromolecules in solution. 20–23 Herein, we further extend the applicability of the electrochemical method at a single entity level, and demonstrate that the activity of a single NP/enzyme hybrid can be detected and quantified.…”
Section: Introductionmentioning
confidence: 99%
“…13 Recently and ‘unrelated at first sight’, a new electrochemical method has emerged 14–16 aiming to unravel electrochemical activity at the single entity level. This electrochemical technique provides the opportunity to characterize single nanoparticles 1719 in situ and large macromolecules in solution. 20–23 Herein, we further extend the applicability of the electrochemical method at a single entity level, and demonstrate that the activity of a single NP/enzyme hybrid can be detected and quantified.…”
Section: Introductionmentioning
confidence: 99%
“…As the average number of expected impacts in a given time interval is proportional to a microdisc's electrode radius as well as to a wire-electrode's length, the sensitivity of both systems can be adjusted via one or the other parameter (taking into account that the overall electrode area is proportional to the capacitance background noise [7,8]). However, in the case of the microdisc, the electrode area increases quadratically with the electrode radius, while the electrode area only increases linearly with the length of the microwire electrode.…”
Section: Comparison Between Microdisc and Microwire Geometriesmentioning
confidence: 99%
“…In the 'nano-impact' method, nanoparticles diffuse freely in an electrochemical cell, and are detected via their stochastic hits on an electrode, which may also be referred to as an 'impact'. Typically, micrometre sized electrodes are used to avoid large capacitance noise [7,8] or simultaneous impacts. During an impact event, the impacting particle may be involved in an electrochemical reaction at the electrode surface, which may result in a direct oxidation of the nanoparticle itself, while a corresponding current is measured [9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…For initial flow cell characterization, an in-house-fabricated 4.15-mm-diameter glassy carbon (GC) electrode was used. Both an Autolab PGSTAT 302N (Metrohm-Autolab, Schiedam, The Netherlands) and an in-house-built low-noise potentiostat 36 (250 Hz sampling rate, 4-pole Bessel filter) were used for all electrochemical experiments.…”
Section: Experimental Sectionmentioning
confidence: 99%