2016
DOI: 10.1016/j.jes.2015.11.034
|View full text |Cite
|
Sign up to set email alerts
|

In situ monitoring of atmospheric nitrous acid based on multi-pumping flow system and liquid waveguide capillary cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
29
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(31 citation statements)
references
References 44 publications
2
29
0
Order By: Relevance
“…Custom-built instruments from FZJ (Forschungszentrum Jülich) and from PKU (Liu et al, 2016) utilized long-path absorption photometry (LOPAP). In addition, three custom-built instruments applied cavity-enhanced absorption spectroscopy (CEAS) for the detection of HONO.…”
Section: Instrumentationmentioning
confidence: 99%
“…Custom-built instruments from FZJ (Forschungszentrum Jülich) and from PKU (Liu et al, 2016) utilized long-path absorption photometry (LOPAP). In addition, three custom-built instruments applied cavity-enhanced absorption spectroscopy (CEAS) for the detection of HONO.…”
Section: Instrumentationmentioning
confidence: 99%
“…To determine of the sample loss of HONO, a HONO standard generator was developed to supply stable concentrations of 10 HONO (Kleffmann et al, 2004;Liu et al, 2016). The schematic of the HONO standard generator is shown in Fig.…”
Section: Sample Lossmentioning
confidence: 99%
“…The measurement is based on artificial OH generation by pulsed laser flash photolysis (LP) of ozone in ambient air combined with the detection of the temporal OH decay by LIF. The method was initially developed for field appli- cation by Sadanaga et al (2004) and is applied today by several other groups (Lou et al, 2010;Parker et al, 2011;Stone et al, 2016). The instrument deployed in this campaign is similar to the instrument described in Lou et al (2010), which was used for measurements in our two field campaigns in 2006 in China.…”
Section: Oh Reactivity Measurementsmentioning
confidence: 99%
“…The method was initially developed for field appli- cation by Sadanaga et al (2004) and is applied today by several other groups (Lou et al, 2010;Parker et al, 2011;Stone et al, 2016). The instrument deployed in this campaign is similar to the instrument described in Lou et al (2010), which was used for measurements in our two field campaigns in 2006 in China. Since then, a second instrument has been built specifically for the deployment on a Zeppelin NT airship , but it can also be operated on the ground.…”
Section: Oh Reactivity Measurementsmentioning
confidence: 99%
See 1 more Smart Citation