In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
47
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 42 publications
(47 citation statements)
references
References 12 publications
0
47
0
Order By: Relevance
“…The GAr and LAr regions are viewed by an array of 255 inward-facing 8 00 diameter Hamamatsu R5912 HQE low radioactivity photomultiplier tubes (PMTs). The characterization of these PMTs is discussed in [11]. These PMTs are optically coupled to 45 cm long UVA acrylic FIG.…”
Section: A Detector Descriptionmentioning
confidence: 99%
See 2 more Smart Citations
“…The GAr and LAr regions are viewed by an array of 255 inward-facing 8 00 diameter Hamamatsu R5912 HQE low radioactivity photomultiplier tubes (PMTs). The characterization of these PMTs is discussed in [11]. These PMTs are optically coupled to 45 cm long UVA acrylic FIG.…”
Section: A Detector Descriptionmentioning
confidence: 99%
“…The following AV PMT characteristics were calibrated before the detector was filled with LAr: (1) the channelto-channel PMT timing variation, which is constrained to <1 ns, (2) the relative channel efficiencies (CEs), which besides the PMTs' quantum efficiencies include the effect of attenuation in the LGs and LG-PMT couplings, and (3) the PMTs' afterpulsing (AP) rates and time distributions [10,11]. Since the LAr fill, the stability of the relative efficiencies and of the afterpulsing rates is monitored continuously, and the PMT single photoelectron (SPE) charge response is calibrated daily to within AE0.3%ðstatÞ AE3%ðsystÞ [11]. The ongoing monitoring and calibration use both an LED light injection system [10,11] and the LAr scintillation light.…”
Section: Pmt Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…The R1408 is far from the cutting edge, so this work also considers what could be achieved if they were were replaced with more modern 8" variants (section 4.5). The PMT referred to as HQE (High Quantum Efficiency) uses efficiency curves and charge distributions measured for the Hamamatsu R5912 [8].…”
Section: Modelmentioning
confidence: 99%
“…The parameter is regularly calibrated for each PMT Using the calibration the PE value for each pulse is measured. Figure is taken from a DEAP-3600 paper which has been recently submitted for publication [68] and was created by other members of the DEAP collaboration.…”
Section: Pementioning
confidence: 99%