2020
DOI: 10.1016/j.microc.2020.105254
|View full text |Cite
|
Sign up to set email alerts
|

In-situ and controllable synthesis of graphene-gold nanoparticles/molecularly imprinted polymers composite modified electrode for sensitive and selective rutin detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 41 publications
0
4
0
Order By: Relevance
“…The number of examples using a molecularly imprinted polymer as the key recognition element was comparable to that of the enzyme-based sensors [ 115 , 122 , 123 , 124 , 173 , 174 , 186 , 191 , 193 , 196 ], indicating that it could represent a promising synthetic receptor to be used instead of a “classical” enzyme.…”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…The number of examples using a molecularly imprinted polymer as the key recognition element was comparable to that of the enzyme-based sensors [ 115 , 122 , 123 , 124 , 173 , 174 , 186 , 191 , 193 , 196 ], indicating that it could represent a promising synthetic receptor to be used instead of a “classical” enzyme.…”
Section: Discussionmentioning
confidence: 96%
“…Several examples introduced screen-printed carbon electrodes, modified with different gold nanomaterials [ 75 , 84 , 85 , 88 , 89 , 93 , 109 , 114 , 115 , 147 , 148 , 161 , 172 , 173 , 186 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…14 When a literature review was conducted on the studies performed for RUT analysis, it was seen that the available studies are based on electrochemical nanosensors, [15][16][17][18][19][20][21][22][23][24][25][26][27] capillary electrophoresis, 28 electrochemiluminescence, 29 high-performance liquid chromatography (HPLC) with an ultraviolet (UV) detector, 8,30 HPLC with a diode array detector, 31 HPLC with chemiluminescence (CL) detection, 32 and molecularly imprinted polymer (MIP)-based electrochemical sensors. [33][34][35][36] Although the mentioned studies offer advantages such as high sensitivity for RUT determination, the most important challenges of chromatographic methods are that they require highly skilled operators, expensive equipment, and labor-intensive procedures. Chromatographic methods have disadvantages such as high cost, complex processing procedures, need for expert personnel and difficulties in the sample preparation phase.…”
Section: Introductionmentioning
confidence: 99%