2002
DOI: 10.1016/s0009-2541(01)00292-3
|View full text |Cite
|
Sign up to set email alerts
|

In situ analysis of trace elements in quartz by using laser ablation inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
57
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 125 publications
(59 citation statements)
references
References 14 publications
1
57
0
Order By: Relevance
“…The analytical error ranges within 10 % of the absolute concentration of the element. Detailed description of the measurement procedures were given by Flem et al (2002) and Flem and Müller (2012). The analysed quartz crystals were examined by scanning electron microscope cathodoluminescence (SEM-CL) using a Centaurus BS Bialkali type CL detector prior to and after LA-ICP-MS analysis in order to relate the analyses to particular crystal growth zones, where growth zoning is developed, and to avoid the analysis of secondary quartz generations.…”
Section: Methodsmentioning
confidence: 99%
“…The analytical error ranges within 10 % of the absolute concentration of the element. Detailed description of the measurement procedures were given by Flem et al (2002) and Flem and Müller (2012). The analysed quartz crystals were examined by scanning electron microscope cathodoluminescence (SEM-CL) using a Centaurus BS Bialkali type CL detector prior to and after LA-ICP-MS analysis in order to relate the analyses to particular crystal growth zones, where growth zoning is developed, and to avoid the analysis of secondary quartz generations.…”
Section: Methodsmentioning
confidence: 99%
“…124 The analysis of CaF 2 , glass, quartz, ceramics, and other multi-component materials is hampered due to spectral interferences, which can be overcome by high mass resolution. [125][126][127][128] This was also recognised as an example for quality control in the steel industry, e.g., for the determination of phosphorus in steel and for the determination of 14 trace elements in cement. 129,130 Multi-element analysis of materials and objects in the context of forensic studies or provenance determination has been described in literature as well.…”
Section: Biological and Environmental Samplesmentioning
confidence: 99%
“…[165][166][167][168][169][170][171] The latter sample materials can reflect the environmental status in water in their element/Ca ratios. 172 Sea water temperatures can be calculated from Mg/Ca ratios in foraminifera since the uptake of Mg into foraminiferal CaCO 3 is temperature-dependent.…”
Section: Geological and Radionuclide Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…These standards have been well characterized in LA-ICPMS studies and provide reliable calibrations for analysis of many geological materials [12,20]. The certified values for the SRM were used; and when that information was unavailable, consensus values were used [20,21]. Aluminum-27 was used as an internal standard (IS) for sector field ICPMS analyses.…”
Section: Calibration and Detection Limitsmentioning
confidence: 99%