2015
DOI: 10.1016/j.bios.2014.08.009
|View full text |Cite
|
Sign up to set email alerts
|

In silico designed nanoMIP based optical sensor for endotoxins monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
55
0

Year Published

2015
2015
2017
2017

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 77 publications
(55 citation statements)
references
References 24 publications
(25 reference statements)
0
55
0
Order By: Relevance
“…MIPs were produced using the glass beads as a solidphase support for the template (Abdin et al, 2015;Altintas et al, 2015b). In 98 mL of double-distilled water, the following components were added; 39 g N-isopropylacrylamide, 2.2 mL acrylic acid, 2 mg N,N′-methylenebisacrylamide, 33 mg N-tert-butylacrylamide, dissolved in 2 mL ethanol, 5.4 mg N-(3-aminopropyl) methacrylamide hydrochloride.…”
Section: Plastic Antibody Synthesis and Characterisationmentioning
confidence: 99%
“…MIPs were produced using the glass beads as a solidphase support for the template (Abdin et al, 2015;Altintas et al, 2015b). In 98 mL of double-distilled water, the following components were added; 39 g N-isopropylacrylamide, 2.2 mL acrylic acid, 2 mg N,N′-methylenebisacrylamide, 33 mg N-tert-butylacrylamide, dissolved in 2 mL ethanol, 5.4 mg N-(3-aminopropyl) methacrylamide hydrochloride.…”
Section: Plastic Antibody Synthesis and Characterisationmentioning
confidence: 99%
“…Targets that are either scarce, unstable or toxic are not useful as templates and here we describe the rational behind the selection of the target substructure. Given the amphiphilic nature of the target, recognition driven by combined hydrophobic and polar interactions is expected to be particularly powerful1011121314. Phosphatidic acid is a phosphomonoester and the common motif of the glycerophospho lipids.…”
mentioning
confidence: 99%
“…Here, we have developed a self-contained, on-chip peristaltic pump using iron filings and PDMS that is driven by magnets and a motor. We have used this magnetic pump to build a diafiltration-on-chip system that can be used to rapidly purify biologically-relevant samples, including small molecules from beads 2022 and beads from cells 23,24 . However, by replacing the membrane filter, the use of the diafiltration-on-chip device may also be extended to include size-based purification of other samples such as extracellular vesicles 25 , proteins 26 , and nanoparticles 3 .…”
Section: Discussionmentioning
confidence: 99%