Abstract: To validate a novel semi-automatic segmentation algorithm for MR-derived volume and function measurements by comparing it with the standard method of manual contour tracing. The new algorithms excludes papillary muscles and trabeculae from the blood pool, while the manual approach includes these objects in the blood pool. An epicardial contour served as input for both methods. Multiphase 2D steady-state free precession short axis images were acquired in 12 subjects with normal heart function and in a dynamic a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
47
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(49 citation statements)
references
References 19 publications
1
47
0
1
Order By: Relevance
“…Epicardial contours were traced by automated contour detection and manually adjusted if necessary. A thresholding algorithm (MassK, Medis) was used to discriminate between LV chamber blood and myocardium without the use of enodocardial contours [7]. This algorithm estimates the signal intensity (SI) of blood and myocardium and calculates a blood percentage (BP) value for any given pixel using the following equation:…”
Section: Threshold-based Cine Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…Epicardial contours were traced by automated contour detection and manually adjusted if necessary. A thresholding algorithm (MassK, Medis) was used to discriminate between LV chamber blood and myocardium without the use of enodocardial contours [7]. This algorithm estimates the signal intensity (SI) of blood and myocardium and calculates a blood percentage (BP) value for any given pixel using the following equation:…”
Section: Threshold-based Cine Evaluationmentioning
confidence: 99%
“…The goal of our study was to evaluate the accuracy and efficiency of a commercially available, threshold-based, semi-automated method [7] for LV functional measurement in comparison to conventional manual contour-based segmentation, with aortic flow measurements as a reference given the lack of a non-MRI gold standard.…”
Section: Introductionmentioning
confidence: 99%
“…Így célul tűztük ki a jobb kamrai üregmére-tek és funkciók vizsgálatát echokardiográfi ával és szív MR-rel, valamint a kapott eredmények összehasonlítá-sát COPD-ben. Az utóbbi években elterjedt módszernek köszönhető-en kétféle elemzési technika használható a vizsgálati eredmények értékelésére (19), így célunk volt annak megítélése is, hogy a hagyományos, manuális kontúro-zással kapott volumen-és funkcióeredményeket meny- …”
Section: Megbeszélésunclassified
“…Coronary microemboli were found to have an acute impact on LV function. The reproducibility of CMR derived LV volume and function measurements were improved using a semi-automatic threshold-based segmentation algorithm [36]. In a confirmatory study of highly trained asymptomatic male endurance athletes, myocardial mass was increased in participates having ECG abnormalities independent of late gadolinium enhancement (LGE) [37].…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%