2020
DOI: 10.1016/j.bios.2020.112111
|View full text |Cite
|
Sign up to set email alerts
|

Improving the reproducibility, accuracy, and stability of an electrochemical biosensor platform for point-of-care use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
44
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 81 publications
(45 citation statements)
references
References 32 publications
0
44
0
1
Order By: Relevance
“…These biosensors vary from each other based on the use of biorecognition components (BRC) and EAT for the detection process [1,4]. Typically, ECBs comprise three electrodes (working electrode (WE), reference electrode (RE), and counter electrode (CE)) that are placed in contact with the analyte solution in an electrochemical cell [1,6,53]. These three electrodes are connected with an electrochemical workstation that is capable of applying potential and measuring the electrochemical changes due to electron transfer at the interfacial region between the WE (transducer) and solution [46,51].…”
Section: Electrochemical Biosensorsmentioning
confidence: 99%
See 3 more Smart Citations
“…These biosensors vary from each other based on the use of biorecognition components (BRC) and EAT for the detection process [1,4]. Typically, ECBs comprise three electrodes (working electrode (WE), reference electrode (RE), and counter electrode (CE)) that are placed in contact with the analyte solution in an electrochemical cell [1,6,53]. These three electrodes are connected with an electrochemical workstation that is capable of applying potential and measuring the electrochemical changes due to electron transfer at the interfacial region between the WE (transducer) and solution [46,51].…”
Section: Electrochemical Biosensorsmentioning
confidence: 99%
“…POCT provides health experts and patients with the opportunity to monitor health conditions and diagnose a disease quickly and accurately. Furthermore, the introduction of personalized heath care would be possible with the large-scale implementation of POCT [6,8,12]. This would allow for Figure 22.…”
Section: Advances In Poct Devices: Prospects and Challenges In The CLmentioning
confidence: 99%
See 2 more Smart Citations
“…In recent years, the development of electrochemical biosensors for DNA biomarkers has been of increasing interest to researchers due to their fast-analytical time, low cost and ease of miniaturization compared with traditional detection methods [ 9 , 10 , 11 , 12 , 13 , 14 ]. However, as the capture probe for electrochemical DNA sensor, single-stranded DNA is not rigid and lacks the ability to modulate the density of probes.…”
Section: Introductionmentioning
confidence: 99%