Improving the quality of voltage in the system of traction power supply of direct current

Abstract: Purpose of the work is improved approaches to ensure the required quality parameters of voltage in the traction network based on modern technologies and equipment in the application of power distribution system. Actuality. The introduction of high-speed traffic, increase weight standards Train necessitates increasing the carrying capacity of railways. Often the carrying capacity of existing sections electrified at 3.0 kV DC power supply unit limits. Such limitations include voltage decrease on the electric cur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
3

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 0 publications
0
7
0
3
Order By: Relevance
“…Replacing 6-pulse rectifiers with 12-pulse rectifiers along with raising rated voltage of the traction network power supply is aimed at achieving the following effects [11][12][15][16][17][18][19][20][21][22]: • improving voltage stability, • reducing losses in the transmission and distribution of electricity, • reducing electricity deformations retrieved from a commercial power system.…”
Section: The Power Supply Systemmentioning
confidence: 99%
“…Replacing 6-pulse rectifiers with 12-pulse rectifiers along with raising rated voltage of the traction network power supply is aimed at achieving the following effects [11][12][15][16][17][18][19][20][21][22]: • improving voltage stability, • reducing losses in the transmission and distribution of electricity, • reducing electricity deformations retrieved from a commercial power system.…”
Section: The Power Supply Systemmentioning
confidence: 99%
“…14. The result of solving must be the control law of the reinforcement point that works as a part of the tracking system for the voltages mode. In general, the current of the reinforcement point may be defined as follows: is the voltage drop in the contact network while accounting for the circulating currents, which is defined by formula (2); in practice its value may be measured with that proposed in [14], a wireless measurement system; ( ) As can be seen from fig. 12 (a) the voltage values in each pantograph of the electric rolling stock does not fall below 2900 V (voltage limit in the pantographs of the electric rolling stock for highspeed or heavyweight movement), which indicates that the voltage stabilization system works acceptably.…”
Section: Application To the Voltage Stabilization Systemmentioning
confidence: 99%
“…Here it is possible to observe frequent unsuccessful acts of regenerative braking of the train, which termination is caused by achievement of voltage on a pantograph the maximal admissible value (4,0 kV) owing to absence in a regenerative zone of trains in the traction mode. In addition, the effectiveness of the modes of regeneration depends on the voltage level at the busbars of traction substations (Sychenko et al, 2015). In this case the energy saving effect from regeneration decreases as the generated energy is utilized by brake mechanisms of the vehicle.…”
Section: Review Of Literature and Problem Statementmentioning
confidence: 99%
“…It is mainly related with a time spread of processes of energy consumption and energy generation by the vehicles which are on a section in the traction and regenerative modes that is especially noticeable in the case of small traffic. Energy quality during regeneration on the buses of substations must also be taken into account (Sychenko et al, 2015). Complex application of the mentioned technologies can improve regenerative modes of the electric power on non autonomous electric transport.…”
Section: Introductionmentioning
confidence: 99%