2008
DOI: 10.1364/ao.47.006692
|View full text |Cite
|
Sign up to set email alerts
|

Improving optical bench radius measurements using stage error motion data

Abstract: We describe the application of a vector-based radius approach to optical bench radius measurements in the presence of imperfect stage motions. In this approach, the radius is defined using a vector equation and homogeneous transformation matrix formulism. This is in contrast to the typical technique, where the displacement between the confocal and cat's eye null positions alone is used to determine the test optic radius. An important aspect of the vector-based radius definition is the intrinsic correction for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 7 publications
0
8
0
Order By: Relevance
“…The system repeatability can be further improved by enhancing the environment stability through strict environmental control. At the same time, the offset between the measurement results and the nominal value can be reduced by compensating for the environmental parameters, misalignment, and motion errors to further improve the accuracy of the system [7,12,13].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The system repeatability can be further improved by enhancing the environment stability through strict environmental control. At the same time, the offset between the measurement results and the nominal value can be reduced by compensating for the environmental parameters, misalignment, and motion errors to further improve the accuracy of the system [7,12,13].…”
Section: Methodsmentioning
confidence: 99%
“…The air-bearing slider is made of granite, with traveling range of 1 m and straightness of 0.5 μm, which can reduce the motion error and radius measurement error effectively [11][12][13]. The system also uses a coaxial design; the optical paths of the differential confocal system and the DMI have been set on the same line, which reduces Abbe error.…”
Section: Design Of Instrumental Structuresmentioning
confidence: 99%
“…The basic principle behind the advanced confocal technique uses the difference in the relative locations of the cats-eye condition (when the focal point is coincident with the apex of surface) and the confocal condition (when the focal point is coincident with the centre of curvature) as a measure of the radius of curvature [15][16][17][18].…”
Section: Measurement Principlementioning
confidence: 99%
“…The main errors having effects on ROC measurement are the distance measurement error of laser interferometer, position errors at cat's-eye position A and confocal position B, wavefront aberrations of sphere measured and axial alignment errors, and so on [3,14,15].…”
Section: Measurement Errorsmentioning
confidence: 99%
“…It can be seen from Eqs. (2) and (15) that the offset ∆z A and ∆z B of points O A and O B are equal, the radius measurement error caused by the VPH axial offset δ is…”
mentioning