Improving Operational Safety of NPP Steam Generators by Controlling Steam Humidity
Viktor Panin,
Maksym Garbar,
Oleksandr Kolomiychenko
et al.
Abstract:The article considers the possibility of increasing the safety of NPP power units operation by improving the quality of steam generator water supply control. The quality of control is improved by introducing a new information signal about steam humidity before the turbine. The necessity of introducing this signal is substantiated. The article describes the properties of the object of regulation by various channels, the initial coordinate for which is steam humidity.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.