2021
DOI: 10.1007/s00066-021-01749-6
|View full text |Cite
|
Sign up to set email alerts
|

Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(13 citation statements)
references
References 20 publications
0
13
0
Order By: Relevance
“…In addition, EPID-based in vivo dosimetrics, which measure transmission images during patient delivery for intensitymodulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), have been demonstrated to be feasible in recent years (10)(11)(12). Fuangrod et al (13) used statistical process control and other methods to compare the consistency of the calculated and actually measured dose accumulation points in real time, and the dose delivery error could be found within 2 s. Miri et al ( 14) used Varian's aS1200 DMI panel to develop a QA model for IMRT delivery verification.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, EPID-based in vivo dosimetrics, which measure transmission images during patient delivery for intensitymodulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), have been demonstrated to be feasible in recent years (10)(11)(12). Fuangrod et al (13) used statistical process control and other methods to compare the consistency of the calculated and actually measured dose accumulation points in real time, and the dose delivery error could be found within 2 s. Miri et al ( 14) used Varian's aS1200 DMI panel to develop a QA model for IMRT delivery verification.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, EPID-based in vivo dosimetrics, which measure transmission images during patient delivery for intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), have been demonstrated to be feasible in recent years ( 10 12 ). Fuangrod et al.…”
Section: Introductionmentioning
confidence: 99%
“…Most studies found in literature analyzing IVD results on a large scale, report deviations of the same type of causes and order of magnitude [5] , [22] , [25] , [26] , [27] but none to our knowledge, have evaluated the impact of changes made to the clinical workflow on the results of their IVD measurements.…”
Section: Discussionmentioning
confidence: 99%
“…EPIDs are present on modern linear accelerators, offering the possibility to perform patient position and dosimetric verification in 2D/3D, and automation [9] , [10] . Several studies have shown the sensitivity and effectiveness of EPID-based IVD (EIVD) for different treatment sites and relevant deviations encountered in clinical routine [11] , [12] , [13] , [14] .…”
Section: Introductionmentioning
confidence: 99%