2015
DOI: 10.1016/j.nimb.2015.08.022
|View full text |Cite
|
Sign up to set email alerts
|

Improvements in PIXE analysis of hourly particulate matter samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
33
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(33 citation statements)
references
References 25 publications
(20 reference statements)
0
33
0
Order By: Relevance
“…Measurements were performed on samples collected with a streaker sampler [34] exploiting the external beam set-up fully dedicated to aerosol analysis available at LABEC. Details on the technique and the set-up, included the X-ray detection system, are given elsewhere [34,35]; here we briefly recall that the streak of collected particles is analysed point-by-point using a proton beam collimated in order to get a spot corresponding to 1-h sampling.…”
Section: Elemental Composition By Streakermentioning
confidence: 99%
See 1 more Smart Citation
“…Measurements were performed on samples collected with a streaker sampler [34] exploiting the external beam set-up fully dedicated to aerosol analysis available at LABEC. Details on the technique and the set-up, included the X-ray detection system, are given elsewhere [34,35]; here we briefly recall that the streak of collected particles is analysed point-by-point using a proton beam collimated in order to get a spot corresponding to 1-h sampling.…”
Section: Elemental Composition By Streakermentioning
confidence: 99%
“…Details on the technique and the set-up, included the X-ray detection system, are given elsewhere [34,35]; here we briefly recall that the streak of collected particles is analysed point-by-point using a proton beam collimated in order to get a spot corresponding to 1-h sampling. Every point was measured for 60 s using a 300 nA beam; elemental concentrations were obtained via calibration relative to thin reference standards.…”
Section: Elemental Composition By Streakermentioning
confidence: 99%
“…The argon in air cannot be ignored behind the thin samples for PIXE analysis . In Figure , a comparison of spectra acquired with and without the helium flow behind the sample is shown.…”
Section: Resultsmentioning
confidence: 99%
“…PIXE analysis has been performed using the external beam PIXE setup at the 3MV Tandetron accelerator of INFN‐LABEC laboratory in Florence, Italy. The experimental setup has been described elsewhere . The essential features are briefly mentioned here.…”
Section: Methodsmentioning
confidence: 99%