Improvement of transient stability of DFIG based wind generator by using of resistive solid state fault current limiter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…The doubly fed induction generator, commonly termed DFIG, is an induction generator with a wound rotor. The rotor is connected to the electrical grid by means of a back-to-back converter [24]. It only requires a partially rated converter, making it cheaper and more efficient than the synchronous generator.…”
Section: Research Motivationmentioning
confidence: 99%
See 1 more Smart Citation
“…The doubly fed induction generator, commonly termed DFIG, is an induction generator with a wound rotor. The rotor is connected to the electrical grid by means of a back-to-back converter [24]. It only requires a partially rated converter, making it cheaper and more efficient than the synchronous generator.…”
Section: Research Motivationmentioning
confidence: 99%
“…The DFIG is simply a WRIG equipped with a back-to-back converter from the grid to the rotor. The converter allows bidirectional power flow [24], [53], [54],. The converter is usually rated at 30% of the machines rated power [11].…”
Section: Types Of Wind Energy Conversion Systemsmentioning
confidence: 99%
“…In order to ensure a proper operation, a cooling equipment is necessary to control the temperature of the superconducting materials, which implies a high cost. In the second category, the semiconductor devices are controlled to inject an additional impedance in series with the system in order to restrict the transient overcurrents 27,31,32 . Certainly, the control of this type remains relatively easy, but it exposes several technical challenges.…”
Section: Proposed Ncfcl Technique During Voltage Dipsmentioning
confidence: 99%
“…These facilities also have gained increasing attention due to increasing penetration of DG units especially wind turbine (WT) type to distribution networks. Application of FCLs has been aimed to realize desirable interaction between WTs and the networks considering different aspects such as low voltage ride through (LVRT) capability, [16][17][18][19][20][21][22][23] transient stability, [24][25][26][27][28] power quality, 29 and wind power smoothing. 30 In the following, a brief description about each aspect is presented:…”
Section: Introductionmentioning
confidence: 99%
“…These facilities also have gained increasing attention due to increasing penetration of DG units especially wind turbine (WT) type to distribution networks. Application of FCLs has been aimed to realize desirable interaction between WTs and the networks considering different aspects such as low voltage ride through (LVRT) capability, transient stability, power quality, and wind power smoothing . In the following, a brief description about each aspect is presented: In a previous study, it is confirmed that different types of FCLs is a suitable option for enhancing the LVRT capability of WTs, which is one of the main requirements of the grid codes for integration of WTs into power system. FCLs are able to improve transient stability of WTs.…”
Section: Introductionmentioning
confidence: 99%