2012
DOI: 10.1016/j.renene.2012.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of the mechanical durability of micro porous layer in a proton exchange membrane fuel cell by elimination of surface cracks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
35
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(37 citation statements)
references
References 23 publications
2
35
0
Order By: Relevance
“…The mechanical AST was based on a literature study [25], but a simpler system was set up and already adopted in Reference [5]. A dummy cell was assembled with two GDMs at anodic and cathodic side, separated by a Nafion 212 pure membrane, namely without any catalyst to avoid any possible chemical or electrochemical stress.…”
Section: Accelerated Stress Testsmentioning
confidence: 99%
“…The mechanical AST was based on a literature study [25], but a simpler system was set up and already adopted in Reference [5]. A dummy cell was assembled with two GDMs at anodic and cathodic side, separated by a Nafion 212 pure membrane, namely without any catalyst to avoid any possible chemical or electrochemical stress.…”
Section: Accelerated Stress Testsmentioning
confidence: 99%
“…To mimic the erosion of GDL over its lifetime solely by gas flow effect, excessive air flow experiments were conducted by Ha [22] and Chun et al [85]. To eliminate the degradation effect of electrochemical reactions, the catalyst layer was removed from the cell.…”
Section: Erosion Of Gdl By Continuous Gas Flowmentioning
confidence: 99%
“…The 2400 h test found that the carbon paper-type GDL showed larger weight loss than the carbon felt-type GDL (paper-type: À1.1%; felt-type: À0.7%), while showing similar static contact angle loss of substrate from approximately 147°to approximately 135°. Chun et al [85] accelerated the mechanical degradation by supplying a high flow rate of air (10 LPM) into the dummy cell of 25 cm 2 . Through 14 days of both dry and humidified gas experiments, they concluded that the damage on the surface of the MPL is mainly due to the water in the humidified air.…”
Section: Erosion Of Gdl By Continuous Gas Flowmentioning
confidence: 99%
“…Thereby, degradation of MPLs with unintended crack formation might cause deterioration of cell performance. Less observation in relation with crack formation under MPL preparation process can be found in the literature (Chun, et al, 2012. Typically, MPLs were fabricated by mixing carbon powder, PTFE dispersion, isopropyl alcohol and distilled water and then applying to a GDL.…”
Section: Manufacturing Processmentioning
confidence: 99%