2017
DOI: 10.1016/j.foodchem.2016.10.008
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of simultaneous determination of neutral monosaccharides and uronic acids by gas chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
38
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 89 publications
(40 citation statements)
references
References 37 publications
1
38
0
Order By: Relevance
“…[21] Monosaccharide composition analysis: The monosaccharide composition analysis of GZMP-1, GZMP-2, GZMP-3, and GZMP-4 was detected by GC analysis as described previously. [22,23] GC (Shimadzu 2014 C; Shimadzu Corp., Kyoto, Japan) with a high-performance capillary column (DB-17; 30 mL × 0.25 mm ID, 0.25-μm film thickness; Agilent Technologies, Santa Clara, CA, USA) was used to determine the neutral monosaccharides' derivatized products.…”
Section: Methodsmentioning
confidence: 99%
“…[21] Monosaccharide composition analysis: The monosaccharide composition analysis of GZMP-1, GZMP-2, GZMP-3, and GZMP-4 was detected by GC analysis as described previously. [22,23] GC (Shimadzu 2014 C; Shimadzu Corp., Kyoto, Japan) with a high-performance capillary column (DB-17; 30 mL × 0.25 mm ID, 0.25-μm film thickness; Agilent Technologies, Santa Clara, CA, USA) was used to determine the neutral monosaccharides' derivatized products.…”
Section: Methodsmentioning
confidence: 99%
“…Hydrolysis of EPSs sample was performed with 2 M trifluoroacetic acid (120 °C, 2 h) and the monosaccharides were reduced with NaBH 4 , neutralised, acetylated as described by Wang et al . () and then analysed by GC‐MS as described by Sun et al . ().…”
Section: Methodsmentioning
confidence: 99%
“…The coefficients of variance were lower than 5% for most compounds and 5.2%-7.2% for the others including GalNAc, GlcNAc, and fructose based on four replicates. Compared to other recently published quantitation methods for monosaccharides including GC-FID, CE-UV, HPAEC-PAD, and LC-MS using an ion trap instrument (Table S1 ) , 3740 the current method employing UHPLC-QqQ with dMRM has proven to be the fastest and most sensitive, while covering a wide range of monosaccharides. Owing to the efficient separation, minimal interference, and targeted detection, the LODs for most PMP-derivatized monosaccharides were improved by > 1000-fold to 0.056-5.6 femtomoles compared to ≥ 9 or 0.7 picomoles obtained by UV or ion trap MS, respectively.…”
Section: Resultsmentioning
confidence: 95%