Eighth International Multi-Conference on Systems, Signals &Amp; Devices 2011
DOI: 10.1109/ssd.2011.5767461
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of fault critical time by HVDC transmission

Abstract: International audienceThis paper investigates the impact of High Voltage Direct Current (HVDC) transmission on the transient stability of a two-machine power system, considering three transmission line configurations: parallel HVAC-HVAC, parallel HVDC-HVDC, and a hybrid HVAC-HVDC operation. The faults are balanced three-phase short-circuits in AC lines, and single phase faults on DC lines, applied in the mid-point of the interconnection. For each configuration, transient stability of the AC systems is assessed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 11 publications
(14 reference statements)
0
6
0
Order By: Relevance
“…where P ac is the per unit active power transmitted by the AC line and P dc is the continuous per unit power of the DC line. According to [17], the strength of an AC line may be quantified by the value of ρ :…”
Section: Hybrid Hvac-shvdc Link Test Power Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…where P ac is the per unit active power transmitted by the AC line and P dc is the continuous per unit power of the DC line. According to [17], the strength of an AC line may be quantified by the value of ρ :…”
Section: Hybrid Hvac-shvdc Link Test Power Systemmentioning
confidence: 99%
“…Many authors have investigated the impact of HVDC applications on stability limits of interconnected power systems [6][7][8][9][10][11][12][13][14][15][16][17]. For transient stability, the criteria used are the 4 Critical Clearing Time (CCT) and the power transfer limit li mit P , called also the dynamic transmission capacity in [18].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Whereas, the initial PTL leads to the same result with a different method. • Similar to [25]- [27], [42], the role of grid strength on the BTBC stability is discussed. However, in this paper, fully VSC-based very weak IMGs are taken into account, which causes a different phenomenon with respect to strong multi-area power systems, i.e.…”
Section: Introductionmentioning
confidence: 99%