2019
DOI: 10.21577/0100-4042.20170391
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of an Analytical Method Based on HPLC With Refractive Index Detection for the Analysis of Glycerol Oxidation Products

Abstract: The optimized analytical methodology described herein is based on an ion exchange column and an H 3 PO 4 solution (pH 2.24) as the mobile phase, with a flow rate of 0.4 mL min-1 and refractive index detection (RID). On applying the methodology, it was possible to identify 7 products obtained from the oxidation of glycerol with an analysis time of 27 min. The developed method was validated through the evaluation of a series of analytical parameters. The results obtained were evaluated considering the peak area … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 26 publications
(26 reference statements)
0
4
0
Order By: Relevance
“…Nevertheless, a significant challenge is the control of the GOR selectivity while simultaneously achieving high reaction rates and high conversions 24,25 since its various reaction pathways often lead to complex mixtures as the final product. 20,21,26 There is currently a limited number of studies reporting highly active GOR catalysts based on earth-abundant materials, 27−31 and even less demonstrating high selectivity toward value-added products. Among them, Ni-based catalysts seem to be promising candidates in terms of catalytic GOR performance, offering relatively low overpotentials and predominant selectivity toward formate.…”
Section: ■ Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, a significant challenge is the control of the GOR selectivity while simultaneously achieving high reaction rates and high conversions 24,25 since its various reaction pathways often lead to complex mixtures as the final product. 20,21,26 There is currently a limited number of studies reporting highly active GOR catalysts based on earth-abundant materials, 27−31 and even less demonstrating high selectivity toward value-added products. Among them, Ni-based catalysts seem to be promising candidates in terms of catalytic GOR performance, offering relatively low overpotentials and predominant selectivity toward formate.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Thus, new methods and technologies for oxalic acid production are rising, some involving electrosynthesis routes. , Hence, the electrochemical synthesis of oxalic acid via the GOR is of great interest for potential industrial applications. Nevertheless, a significant challenge is the control of the GOR selectivity while simultaneously achieving high reaction rates and high conversions , since its various reaction pathways often lead to complex mixtures as the final product. ,, There is currently a limited number of studies reporting highly active GOR catalysts based on earth-abundant materials, and even less demonstrating high selectivity toward value-added products. Among them, Ni-based catalysts seem to be promising candidates in terms of catalytic GOR performance, offering relatively low overpotentials and predominant selectivity toward formate. ,, While some studies demonstrate the formation of C2 or C3 products, improved selectivity still represents a major challenge. …”
Section: Introductionmentioning
confidence: 99%
“…The proposed method shows lower detectability of other extraction methods with HPLC-RID analysis. 14,49,50…”
Section: Resultsmentioning
confidence: 99%
“…The proposed method shows lower detectability of other extraction methods with HPLC-RID analysis. 14,49,50 Analytical parameters of linearity, range, and sensitivity were obtained from the construction of analytical curves for glycerol. Fig.…”
Section: Validation Of the Sbse-hplc-rid Methodsmentioning
confidence: 99%