2017
DOI: 10.1016/j.talanta.2017.06.067
|View full text |Cite
|
Sign up to set email alerts
|

Improved voltammetric method for simultaneous determination of Pt and Rh using second derivative signal transformation – application to environmental samples

Abstract: The determination of Platinum-group elements (PGE) in relevant environmental matrices is a challenging task. Sensitive and accurate analytical procedures for simultaneous determination of Pt and Rh are still needed. In this study, we report for the first time on the use of second derivative signal transformation to the ultra-trace simultaneous determination of Pt and Rh by Adsorptive Cathodic Stripping Voltammetry (AdCSV). With that step, the ill-defined peaks typically observed in the original voltammograms a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 31 publications
0
10
0
Order By: Relevance
“…As to elemental characterization, total carbon (C), hydrogen (H), nitrogen (N) and sulphur (S) were determined using a TruSpec CHNS micro analyser (LECO). The instrument is a dry combustion type with infrared detection for CHS and thermal conductivity detection for N. As to Pt and Rh, both elements were determined after acid-digestion in aqua regia by AdCSV, as previously described in Monteiro et al (2017). The quantification of Pt and Rh was done using the standard addition method.…”
Section: Road Dust Characterizationmentioning
confidence: 99%
See 2 more Smart Citations
“…As to elemental characterization, total carbon (C), hydrogen (H), nitrogen (N) and sulphur (S) were determined using a TruSpec CHNS micro analyser (LECO). The instrument is a dry combustion type with infrared detection for CHS and thermal conductivity detection for N. As to Pt and Rh, both elements were determined after acid-digestion in aqua regia by AdCSV, as previously described in Monteiro et al (2017). The quantification of Pt and Rh was done using the standard addition method.…”
Section: Road Dust Characterizationmentioning
confidence: 99%
“…The truly dissolved fraction of Pt and Rh was determined by AdCSV following the procedure optimized previously (Monteiro et al, 2017). Briefly, voltammetric determinations were performed in an Autolab PGSTAT 12 (Metrohm) connected to the VA stand model 663 (Metrohm).…”
Section: Determination Of Truly Dissolved Pt and Rh In The Leachatesmentioning
confidence: 99%
See 1 more Smart Citation
“…Surface water drainage effluents from hospitals with an oncology ward contain patient excretions of Pt-based anticancer drugs and display Pt concentrations that could exceed natural inputs (Vyas et al 2014). Monteiro et al (2017) evaluated Pt D concentrations in the inflow and outflow of a wastewater treatment plant (WWTP) in Lisbon as ,5 and 15 ng L À1 respectively after a dry weather period and ,10 and 25 ng L À1 after a rain event. In the western part of the Genoa Harbor, Pt inputs from sewage treatment plants reach the Polcevera river mouth (Fig.…”
Section: Hospital and Sewage Effluentsmentioning
confidence: 99%
“…We used the secondderivative transformation signal as it was more efficient in eliminating the background interferences. (20)…”
Section: Measurement Proceduresmentioning
confidence: 99%