2019
DOI: 10.1016/j.ejrad.2019.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Improved visualization of the coronary arteries using motion correction during vasodilator stress CT myocardial perfusion imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…Regions of interest were also placed on the proximal RCA, LAD, and LCX to measure the CT attenuation value (CT vessel ) of each vessel and the noise of these vessels (SD vessel ). Then, the signal-to-noise ratio (SNR) of each vessel was calculated as CT vessel /SD vessel , and the contrast-to-noise ratio (CNR) was calculated as (CT vessel − CT fat )/SD fat 14,15 . Care was taken to avoid confounding structures, such as plaques and vessel wall, in each ROI.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Regions of interest were also placed on the proximal RCA, LAD, and LCX to measure the CT attenuation value (CT vessel ) of each vessel and the noise of these vessels (SD vessel ). Then, the signal-to-noise ratio (SNR) of each vessel was calculated as CT vessel /SD vessel , and the contrast-to-noise ratio (CNR) was calculated as (CT vessel − CT fat )/SD fat 14,15 . Care was taken to avoid confounding structures, such as plaques and vessel wall, in each ROI.…”
Section: Methodsmentioning
confidence: 99%
“…Then, the signal-to-noise ratio (SNR) of each vessel was calculated as CT vessel /SD vessel , and the contrast-to-noise ratio (CNR) was calculated as (CT vessel − CT fat )/ SD fat . 14,15 Care was taken to avoid confounding structures, such as plaques and vessel wall, in each ROI. All measurements were conducted 3 times, and the average value was used for statistical analysis.…”
Section: Objective Image Quality Evaluationmentioning
confidence: 99%
“…Motion-correction algorithms have been investigated for single-source CT (SSCT), some of which are available on commercial scanners (Fuchs et al 2014, Symons et al 2016, Balaney et al 2019. These techniques can improve visualization of coronary arteries in some cases, but yield limited diagnostic quality in patients with high and irregular heart rates (Koplay et al 2016, Machida et al 2016, Liang et al 2017.…”
Section: Introductionmentioning
confidence: 99%