2020
DOI: 10.1016/j.mayocpiqo.2019.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Improved Treatment Response Following Magnetic Resonance Imaging–Guided Focused Ultrasound for Lumbar Facet Joint Pain

Abstract: Magnetic resonance imagingeguided focused ultrasound (MRgFUS) is a noninvasive modality that allows for precise tissue ablation with sparing of surrounding structures. Early reports of the use of MRgFUS for the treatment of facet joint osteoarthritis are promising. We present a case of facet joint pain treated successfully by MRgFUS at our institution. Magnetic resonance imagingeguided focused ultrasonography may be a useful modality for patients with facet jointemediated low back pain, particularly in the set… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…We report a first case of MRgFUS ablation of lumbar facet joints in a patient with refractory low back pain and MRI non-conditional pacemaker. Facet joint MRgFUS is a relatively new treatment for facet joint pain 8,10,11 ; this procedure has the advantage of not requiring skin incision, and uses MRI for treatment planning and monitoring of the ablation in the real-time.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…We report a first case of MRgFUS ablation of lumbar facet joints in a patient with refractory low back pain and MRI non-conditional pacemaker. Facet joint MRgFUS is a relatively new treatment for facet joint pain 8,10,11 ; this procedure has the advantage of not requiring skin incision, and uses MRI for treatment planning and monitoring of the ablation in the real-time.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, MRgFUS ablation treatment of the bilateral L3-4, L4-5, and L5-S1 facet joint capsules was performed as has been described previously. 8 The patient's medical history was significant for coronary artery disease, hypertension, and symptomatic sinus bradycardia (50 beats/ min and 2:1 block), which led to placement of a dual chamber transvenous pacemaker system in 2015 (Assurity DR 2240 pulse generator, Model 1642T right atrial lead, Model 1646T right ventricular lead, all MRI nonconditional, Abbott, IL) in the right chest. The patient was not pacemaker-dependent.…”
Section: Clinical Presentationmentioning
confidence: 99%
See 3 more Smart Citations