2011
DOI: 10.1016/j.jfluidstructs.2011.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Improved transient water wave technique for the experimental estimation of ship responses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…This phase-based harmonic separation method relies on a Stokes-like structure of the studied wave-driven response. It has been used to analyse various nonlinear wave phenomena involving fixed (Fitzgerald et al 2014;Zhao et al 2017;Chen et al 2018) and floating (Roux de Reilhac et al 2011;Chen et al 2021) offshore structures, as well as higher-order responses in coastal problems (Orszaghova et al 2014;Whittaker et al 2017;Judge et al 2019). The above studies utilise short deterministic wave groups.…”
Section: Identifying Nonlinear Resonant Responsesmentioning
confidence: 99%
“…This phase-based harmonic separation method relies on a Stokes-like structure of the studied wave-driven response. It has been used to analyse various nonlinear wave phenomena involving fixed (Fitzgerald et al 2014;Zhao et al 2017;Chen et al 2018) and floating (Roux de Reilhac et al 2011;Chen et al 2021) offshore structures, as well as higher-order responses in coastal problems (Orszaghova et al 2014;Whittaker et al 2017;Judge et al 2019). The above studies utilise short deterministic wave groups.…”
Section: Identifying Nonlinear Resonant Responsesmentioning
confidence: 99%
“…These waves contain broad band frequency content that allow the response as a function of frequency to be obtained from a single test using a DFT analysis. Similar to Roux de Reilhac et al (2011), a modified periodogram technique (Welch's method) was applied to extract RAOs as smooth curves.…”
Section: Response Amplitude Operatorsmentioning
confidence: 99%
“…The parameters defining the first control signal the focal point is located at x f frequency bandwidth is ∆f = 0.33 Hz, the central frequency π. The wave packet is built with a constant steepness spectrum, this avoids premature wave breaking as all the components within the wave packet maintain the same scale respect to wave steepness, Reilhac et al, (2011). The experimental layout used for the tests is shown in Fig.…”
Section: Focused Wave In Constant Water Depthmentioning
confidence: 99%