2001
DOI: 10.1093/jat/25.2.137
|View full text |Cite
|
Sign up to set email alerts
|

Improved Solid-Phase Extraction Method for Systematic Toxicological Analysis in Biological Fluids

Abstract: A method for the simultaneous qualitative and quantitative determination of drugs of abuse (opiates, cocaine, or amphetamines) and prescribed drugs (tricyclic antidepressants, phenotiazines, benzodiazepines, etc.) in biological fluids--blood, urine, bile, and gastric contents--was developed. This procedure involves solid-phase extraction with Bond-Elut Certify columns followed by analysis by gas chromatography-nitrogen-phosphorus detection (GC-NPD) and confirmation by gas chromatography-mass spectrometry (GC-M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
30
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(34 citation statements)
references
References 19 publications
4
30
0
Order By: Relevance
“…The average within-day precision and accuracy of the proposed method as determined at 0.2 and 5 µg ml −1 (n = 10) in bile and vitreous humor are listed in Table 2. The results are similar to those reported by Vanbinst et al (2002), and lower than those obtained by Soriano et al (2001).…”
Section: Resultssupporting
confidence: 89%
“…The average within-day precision and accuracy of the proposed method as determined at 0.2 and 5 µg ml −1 (n = 10) in bile and vitreous humor are listed in Table 2. The results are similar to those reported by Vanbinst et al (2002), and lower than those obtained by Soriano et al (2001).…”
Section: Resultssupporting
confidence: 89%
“…In the preceding methods, the analysis took place on normal-phase chromatographic columns using more expensive, pollutant and toxic mobile phases, such as n-hexane:2-propanol, n-hexane:ethanol or n-hexane:ethanol:2-propanol. Besides the specific chromatographic conditions, the SPE procedure used here in sample pretreatment offers many other benefits over the traditional liquid-liquid extraction methods, such as faster sample preparation, lower cost, greater recoveries, less sample handling, improved safety and easy automation (Soriano et al, 2001;Camel, 2003). Even though ESL and its metabolites could be analyzed using MS detection systems (Hainzl et al, 2001;Almeida et al, 2005), most hospitals and laboratories are not equipped with such high-cost instruments (Velpandian et al, 2004;Janchawee et al, 2007).…”
Section: Discussionmentioning
confidence: 99%
“…The sensitivity showed by our method using GC/MS was similar to that previously reported by using chromatographic methods. [15][16] Table 3 shows the results obtained for intra-assay and inter-assay precision calculations and selected ions used for qualification and quantification of all the analytes. Inter-day and intra-day precision were < 9.0% and <3.5% for all analytes.…”
Section: Resultsmentioning
confidence: 99%