2016
DOI: 10.1177/1045389x16667556
|View full text |Cite
|
Sign up to set email alerts
|

Improved shunt damping with two negative capacitances: An efficient alternative to resonant shunt

Abstract: is an open access repository that collects the work of Arts et Métiers ParisTech researchers and makes it freely available over the web where possible. Abstract This paper deals with piezoelectric shunt damping enhanced with negative capacitances. A novel electrical circuit layout is addressed, based on the use of two negative capacitances. It is shown that the shunt performances, in terms of vibration reduction and stability margins, are increased as compared with the classical single negative capacitance lay… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
31
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(33 citation statements)
references
References 21 publications
(42 reference statements)
2
31
0
Order By: Relevance
“…Tuned mass damper performs well at the design point but are not very robust, and linear lanchester damper appears to be superior with relation to robustness. The same results hold for their electromechanical analogs [3,12].…”
Section: Introductionsupporting
confidence: 68%
See 1 more Smart Citation
“…Tuned mass damper performs well at the design point but are not very robust, and linear lanchester damper appears to be superior with relation to robustness. The same results hold for their electromechanical analogs [3,12].…”
Section: Introductionsupporting
confidence: 68%
“…One can notice that the efficiency A dB of the linear Lanchester damper, if it has been carefully optimized with Eqs. (12) or (20), depends on only one parameter: the mass ratio µ.…”
Section: Direct Numerical Methods For Computing a Dbmentioning
confidence: 99%
“…There are two conditions for the SP configuration because there are two NCs in the circuit. Notably, the conditions of equations (17) to (19) are equal to those found in Berardengo et al (2016b, 2017) for a resistive shunt coupled to NCs.…”
Section: Stability and Performancementioning
confidence: 94%
“…The series and SP NC layouts make the SC eigenfrequency shift towards increasingly lower frequency values (Berardengo et al, 2016b(Berardengo et al, , 2017De Marneffe and Preumont, 2008). When such a shift is high (i.e.…”
Section: Attenuation Performancementioning
confidence: 99%
See 1 more Smart Citation