2019
DOI: 10.1016/j.aca.2019.06.019
|View full text |Cite
|
Sign up to set email alerts
|

Improved segmented-scan spectral stitching for stable isotope resolved metabolomics (SIRM) by ultra-high-resolution Fourier transform mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 37 publications
0
5
0
Order By: Relevance
“…Such SIM with longer transients increases sensitivity, RP, and mass accuracy, thereby improving the chances of polyisotopes and other minor constituents to be observed. This approach has previously been applied for the measurement of isotopic abundance and confirmation of formula assignments. Here, a narrow SIM spectrum obtained in aFT mode ( m/z 378.06–405.26; measured RP = 2 200 000 at m/z 400; number of scans = 100) yielded 54 monoisotopic CHOP formulae, of which 20.4% ( n = 11) had their corresponding isotopic peak detected with up to two 13 C atoms. In comparison, in the broadband aFT spectrum (observed RP at m/z 400 = 1 200 000; number of scans = 1000), only two of the 55 monoisotopic CHOP species (3.6%) in the same m/z range had a corresponding 13 C 1–2 isotopic peak detected.…”
Section: Resultsmentioning
confidence: 99%
“…Such SIM with longer transients increases sensitivity, RP, and mass accuracy, thereby improving the chances of polyisotopes and other minor constituents to be observed. This approach has previously been applied for the measurement of isotopic abundance and confirmation of formula assignments. Here, a narrow SIM spectrum obtained in aFT mode ( m/z 378.06–405.26; measured RP = 2 200 000 at m/z 400; number of scans = 100) yielded 54 monoisotopic CHOP formulae, of which 20.4% ( n = 11) had their corresponding isotopic peak detected with up to two 13 C atoms. In comparison, in the broadband aFT spectrum (observed RP at m/z 400 = 1 200 000; number of scans = 1000), only two of the 55 monoisotopic CHOP species (3.6%) in the same m/z range had a corresponding 13 C 1–2 isotopic peak detected.…”
Section: Resultsmentioning
confidence: 99%
“…Within the measured data set of 622 pixels generating [Ag + C 8 H 10 ] + , the ratio was 1.15 ± 0.41. Therefore, an isotopic component of ion signals can be missing in the mass spectra in the case of ions with intensities close to the noise level because software can falsely attribute low-intensity signals to noise . Note that we did not have any control of the internal data processing and did not modify it.…”
Section: Data Processingmentioning
confidence: 99%
“…The precursor ion filtering of the quadrupole, the quantification of the precursor in the orbitrap, and the parallel identification of fragmentation spectra in the LIT are combined. Researchers had developed SIM stitching techniques based on the LIT or QMS on high-resolution ion trap mass spectrometers such as ICR and Orbitrap (Southam et al, 2007;Kang et al, 2019). Multiple narrow SIM segments were collected together after acquisition to produce a wide range of spectra.…”
Section: Combination Of Orbitrap and Other Analyzersmentioning
confidence: 99%