2020
DOI: 10.1109/jsyst.2019.2958819
|View full text |Cite
|
Sign up to set email alerts
|

Improved Power Quality in a Solar PV Plant Integrated Utility Grid by Employing a Novel Adaptive Current Regulator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(20 citation statements)
references
References 33 publications
0
17
0
Order By: Relevance
“…The system is considered nonlinear behavior due to parameter changes, power electronic devices, variations in temperature in passive components, aging effects, etc. The Lyapunov stability theorem is considered to find out the dynamics of the proposed system 9 for analyzing stability, asymptotic, and exponential stability. Figure 4 shows the bode plot of the proposed control scheme with conventional FONF, which shows the effectiveness of the proposed control F I G U R E 5 (A) Conventional fractional order notch filter (FONF) and (B) equivalent block diagram of improved fractional order notch filter (IFONF) scheme in terms of dc-offset.…”
Section: Proposed Control Schemementioning
confidence: 99%
“…The system is considered nonlinear behavior due to parameter changes, power electronic devices, variations in temperature in passive components, aging effects, etc. The Lyapunov stability theorem is considered to find out the dynamics of the proposed system 9 for analyzing stability, asymptotic, and exponential stability. Figure 4 shows the bode plot of the proposed control scheme with conventional FONF, which shows the effectiveness of the proposed control F I G U R E 5 (A) Conventional fractional order notch filter (FONF) and (B) equivalent block diagram of improved fractional order notch filter (IFONF) scheme in terms of dc-offset.…”
Section: Proposed Control Schemementioning
confidence: 99%
“…To conclude, based on the existing scientific literature, it is presumed that the emerging topic of multiple PV inverters (employing various anti-islanding protection algorithms) at the same PCC has not been sufficiently investigated yet [23,24]. At this point, it is imperative to highlight that some sophisticated anti-islanding schemes that use advanced techniques for the mitigation of current harmonics components, such as [25][26][27][28], are excluded from this study, due to the fact that they have not been widely employed by commercial PV inverters yet. It is recalled that this study focuses on the cooperative response of the commercial PV inverters, which are widely used and established in markets.…”
Section: Introductionmentioning
confidence: 99%
“…Harmonic sources are not only energy consumers but also power electronics-based generators can be important sources of harmonic generation in the network. These harmonic sources can reduce the harmonic output and improve power quality indices by installing proper filters or optimising system control [2,3].…”
Section: Introductionmentioning
confidence: 99%