Improved Performance in Measurement of Serum Cystatin C by Laboratories Participating in the College of American Pathologists 2019 CYS Survey

Abstract: Context.— Use of cystatin C for glomerular filtration rate estimation (eGFR) has garnered heightened interest as a means to avoid race-based medicine, since eGFRcys equations do not require specification of race. Before considering more widespread use of cystatin C, it is important to confirm that assays provide accurate measurements of cystatin C concentration, to ensure accurate GFR estimates. Objective.— To determine if th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…While a certified reference material for cysC (ERM-DA471/IFCC) is available, there are currently no certified reference measurement procedures for cysC to definitively establish target values for the cysC reference material [ 33 ]. However, studies have shown that manufacturers have markedly improved the accuracy and between-method agreement of cysC measurement procedures since 2014, which allows for greater confidence in eGFR relying on cysC [ 34 , 35 ]. For example, standardization of the Roche Gen2 assay improved the accuracy of cysC measurement compared to that of the Siemens assay [ 34 ].…”
Section: Cystatin Cmentioning
confidence: 99%
See 1 more Smart Citation
“…While a certified reference material for cysC (ERM-DA471/IFCC) is available, there are currently no certified reference measurement procedures for cysC to definitively establish target values for the cysC reference material [ 33 ]. However, studies have shown that manufacturers have markedly improved the accuracy and between-method agreement of cysC measurement procedures since 2014, which allows for greater confidence in eGFR relying on cysC [ 34 , 35 ]. For example, standardization of the Roche Gen2 assay improved the accuracy of cysC measurement compared to that of the Siemens assay [ 34 ].…”
Section: Cystatin Cmentioning
confidence: 99%
“…However, despite the improved performance of cysC measurement procedures, the accuracy and between-method agreement of cysC fall well short of those of creatinine, which still is the most widely accepted filtration marker for GFR estimation. Moreover, while at present, all cysC assay kits are traceable to the ERM-DA471/IFCC reference material, ERM-DA471/IFCC-non-traceable kits were still distributed to users of older Siemens platforms, such as the ADVIA Centaur and Siemens Dimension Vista, until the end of 2020 [ 35 ]. The old Siemens Cystatin C assay for the ADVIA Chemistry and Atellica CH platforms was taken from the market in 2020 and replaced with Cystatin C_2, which is traceable to ERM-DA471 (Siemens private communication).…”
Section: Cystatin Cmentioning
confidence: 99%
“…25 However, the 2019 General Chemistry Survey of the College of American Pathologists showed that only 7% of U.S. clinical laboratories offered CysC tests, with >90% of these labs referring CysC testing to external commercial labs. 26 Concerns for assay accuracy and agreement across laboratories have impeded broader clinical CysC adoption. To address these concerns, certified reference materials (ERM-DA471/IFCC), which enable assay manufacturers to calibrate their methods, were made available in 2010.…”
Section: Health System-related Barriers To Adopting Cystatin C Testingmentioning
confidence: 99%
“…In a 2020 survey of a subset of nephrology respondents of the International Society of Nephrology Global Kidney Health Atlas, 67% reported that CysC testing was available within their region (25). However, the 2019 General Chemistry Survey of the College of American Pathologists showed that only 7% of US clinical laboratories offered CysC tests, with >90% of these labs referring CysC testing to external commercial labs (26).…”
Section: Health System–related Barriers To Adopting Cysc Testingmentioning
confidence: 99%
See 1 more Smart Citation