Abstract: Optogalvanic detectors show great potential for infrared spectroscopy, especially in cavity enhanced techniques where they, in contrast to ordinary absorption detectors, can perform intracavity measurements. This enables them to utilize the signal-to-noise ratio improvement gained from the extended effective path length inside an optical cavity, without losing signal strength due to the limited amount of light exiting through the rear mirror.However, if optogalvanic detectors are to become truly competitive, t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2015
2015
2016
2016

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(32 citation statements)
references
References 29 publications
0
32
0
Order By: Relevance
“…The values for these fusings were not logged but rather extrapolated from other events given the voltage and current settings. Figure 12 shows a comparison between one of these probes and a cylindrical probe from [12] when evaluated as Langmuir probes in the SSRR plasma source. From Langmuir probe theory, it is evident that a properly functioning, spherical Langmuir probe should exhibit a higher saturation current at positive bias above the plasma potential compared with a cylindrical one [15].…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…The values for these fusings were not logged but rather extrapolated from other events given the voltage and current settings. Figure 12 shows a comparison between one of these probes and a cylindrical probe from [12] when evaluated as Langmuir probes in the SSRR plasma source. From Langmuir probe theory, it is evident that a properly functioning, spherical Langmuir probe should exhibit a higher saturation current at positive bias above the plasma potential compared with a cylindrical one [15].…”
Section: Discussionmentioning
confidence: 99%
“…The wire was stretched between the pads in the same manner as with the test array in figure 1, between the two probepads. The wire was fused with a voltage and current limit of 25 V and 5 A, respectively, to form two spherical Langmuir probes, replacing the cylindrical probes used in previous studies [10,11,12]. For a description of the positioning of the plasma probes inside the SSRR see [10].…”
Section: Methodsmentioning
confidence: 99%