2017
DOI: 10.1109/tpel.2016.2573823
|View full text |Cite
|
Sign up to set email alerts
|

Improved Modulation Scheme for Loss Balancing of Three-Level Active NPC Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 85 publications
(25 citation statements)
references
References 19 publications
0
25
0
Order By: Relevance
“…The employment of several VSCs in the hybrid system with different active/reactive power controls has made the estimations of the power losses of the converters of prime concern. The power losses modeling in this paper has been carried out in MATLAB based on numerical circuit simulations using the same basics in [30]. The power losses due to the operation of the three-level T-type inverter are analytically determined based on practical datasheet parameters from the manufacturer.…”
Section: Power Losses Analysismentioning
confidence: 99%
“…The employment of several VSCs in the hybrid system with different active/reactive power controls has made the estimations of the power losses of the converters of prime concern. The power losses modeling in this paper has been carried out in MATLAB based on numerical circuit simulations using the same basics in [30]. The power losses due to the operation of the three-level T-type inverter are analytically determined based on practical datasheet parameters from the manufacturer.…”
Section: Power Losses Analysismentioning
confidence: 99%
“…Additionally, NPC topology does not produce common-mode (CM) current, thus it is more suitable for PV generation systems [3,4] and can support longer device lifetime with a lower instantaneous rate of voltage change (dv/dt) [5]. However, NPC topology suffers from unequal heat distribution among the semiconductor devices owing to uneven power loss distribution, as reported in [6][7][8][9]. To overcome this problem, the active clamped diodes were replaced by active switches, achieving and an active neutral point clamped (ANPC) topology [9].…”
Section: Introductionmentioning
confidence: 99%
“…However, the controller cannot realize accurate offline segmentation due to the huge data storage. Considering the unbalanced power losses of power switches in three-level neutral-point-clamped (NPC) grid-connected inverter, References [19] advises to balance the losses of power switches and elevate the maximum output power of the system by replacing the traditional three-level NPC inverter with threelevel ANPC inverter.…”
Section: Introductionmentioning
confidence: 99%