2011
DOI: 10.1080/15421406.2011.572025
|View full text |Cite
|
Sign up to set email alerts
|

Improved Method for the Dispersion of Refractive Indices Based on Transmission Spectroscopic Ellipsometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Here, the elastic constants of the mixture of 5CB and the merocyanine dye were assumed to be the same as those of pure 5CB, i.e., K 11 6.37, K 22 3.81, and K 33 8.60 pN at 25°C. The refractive indices of ordinary and extraordinary rays for 5CB, which were preliminarily determined in our previous study [22,23], are listed in Table 1.…”
Section: Methodsmentioning
confidence: 99%
“…Here, the elastic constants of the mixture of 5CB and the merocyanine dye were assumed to be the same as those of pure 5CB, i.e., K 11 6.37, K 22 3.81, and K 33 8.60 pN at 25°C. The refractive indices of ordinary and extraordinary rays for 5CB, which were preliminarily determined in our previous study [22,23], are listed in Table 1.…”
Section: Methodsmentioning
confidence: 99%
“…Based on plural incidence renormalized transmission spectroscopic ellipsometry, the wavelength dispersion associated with birefringence was assessed using both the TN and ECB cells. Details of these measurement procedures have been provided in a previous paper [21]. The LC texture was examined by crossed nicols polarizing optical microscopy (POM, Eclipse LV100 POL, Nikon, Tokyo, Japan).…”
Section: Methodsmentioning
confidence: 99%
“…By using the extended Cauchy equation, the expression of the refractive indices of ordinary and extraordinary rays of NLC is described as centernnormaloλ=α0+α2λ2+α4λ4centernnormaleλ=β0+β2λ2+β4λ4,where α i and β i represent the i th Cauchy coefficients and λ is the wavelength in micrometers. The Cauchy coefficients of ZLI‐4792 are shown in Table and were determined by means of RTE …”
Section: Experimental Methodsmentioning
confidence: 99%
“…The Cauchy coefficients of ZLI-4792 are shown in Table 2 and were determined by means of RTE. 19,23,24 In this experiment, a color filter laminated on a glass substrate is employed. Here, the alternating stripe patterns of red, green, and blue of color filters are 100 mm, and the thickness of the glass substrate is 0.7 mm.…”
Section: Renormalized Transmission Ellipsometry On An Lc Cell Equippementioning
confidence: 99%