Abstract: Background CMR typically quantifies LV mass (LVM) via manual planimetry (MP), but this approach is time consuming and does not account for partial voxel components - myocardium admixed with blood in a single voxel. Automated segmentation (AS) can account for partial voxels, but this has not been used for LVM quantification. This study used automated CMR segmentation to test the influence of partial voxels on quantification of LVM. Methods and Results LVM was quantified by AS and MP in 126 consecutive patient… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
1
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 52 publications
(25 citation statements)
references
References 37 publications
(66 reference statements)
1
21
1
2
Order By: Relevance
“…Cine-CMR images were used to quantify within each aortic segment: measurements at end of systole and end of diastole were obtained via previously validated automated MRI segmentation algorithm (LV-METRIC) ( Figure 1). In prior validation studies, LV-METRIC closely agrees with phantom-based cardiac volumetric indices and is high reproducible for cardiac chamber geometry measurements (13,14). Per-patient analyses were performed by a skilled investigator (>5 years experience) who was blinded to diagnosis and clinical characteristics.…”
Section: Aortic Dimensions and Stiffness Measurementsmentioning
confidence: 90%
See 1 more Smart Citation
“…Cine-CMR images were used to quantify within each aortic segment: measurements at end of systole and end of diastole were obtained via previously validated automated MRI segmentation algorithm (LV-METRIC) ( Figure 1). In prior validation studies, LV-METRIC closely agrees with phantom-based cardiac volumetric indices and is high reproducible for cardiac chamber geometry measurements (13,14). Per-patient analyses were performed by a skilled investigator (>5 years experience) who was blinded to diagnosis and clinical characteristics.…”
Section: Aortic Dimensions and Stiffness Measurementsmentioning
confidence: 90%
“…In this study, we applied an automated segmentation CMR algorithm, developed and validated by our group, that affords partial voxel interpolation (PVI) of aortic lumen size (cross-sectional areas) throughout the cardiac cycle (systole and diastole) to assess aortic stiffness (13,14). In prior studies, PVI yielded improved agreement of CMR measures with phantom-based cardiac volumetric indices and necropsy left ventricular myocardial mass.…”
Section: Introductionmentioning
confidence: 99%
“…Магнитнорезонансная томография (МРТ) сердца может рассматриваться как метод оценки размера и массы левого желудочка в тех случаях, когда эхо-кардиография технически невыполнима, а также, если визуализация с отсроченным усилением даст информацию, имеющую значение для выбора лече-ния [175,176].…”
Section: магнитнорезонансная томография сердцаunclassified
“…Rezonans magnetyczny (MRI) serca należy rozważać w celu oceny wielkości i masy lewej komory, kiedy echokardiografia nie jest technicznie możliwa i gdy obrazowanie z oceną opóźnionego wzmocnienia po dożylnym podaniu środka kontrastowego (delayed enhancement) miałoby konsekwencje terapeutyczne [175,176].…”
Section: Rezonans Magnetyczny Sercaunclassified