Improved Insulation Durability to Improve Transformer Aging

Abstract: In transformers, in addition to the primary and secondary coils, there are several other important components and accessories in which the insulating material is one of the most critical components of a transformer. Sufficient insulation between different active parts are necessary for safe operation. Adequate insulation, it is not only necessary to insulate the coils from each other, or from the core and tank, but also guarantees the safety of the transformer against accidental surges, but with the growth in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…As seen in Fig. (6) there is no PD activity at the rated voltage of the coil applied for 5 hours and the entire graph simply consists of spikes that are probably due to small electromagnetic noise present in the environment and noise picked up within the measuring circuit. Moreover, the very small amount of noise detected may perhaps also be due to slight corona that may occur inside the tank as the distance of coil from the walls of the enclosure tank was less than that in actual transformer assembly.…”
Section: A Pd Activity In Coilmentioning
confidence: 98%
See 1 more Smart Citation
“…As seen in Fig. (6) there is no PD activity at the rated voltage of the coil applied for 5 hours and the entire graph simply consists of spikes that are probably due to small electromagnetic noise present in the environment and noise picked up within the measuring circuit. Moreover, the very small amount of noise detected may perhaps also be due to slight corona that may occur inside the tank as the distance of coil from the walls of the enclosure tank was less than that in actual transformer assembly.…”
Section: A Pd Activity In Coilmentioning
confidence: 98%
“…Throughout its service life, a transformer is under the influence of cyclic chem-ical, electrical, thermal, mechanical, and electromagnetic stresses during normal and ab-normal load conditions [4]. The transformer insulation is subjected to different stresses and degrades gradually during operation, depending on the duration and magnitude of overvoltage which results in the core overheating and overstressing the insulation [5,6]. Sometimes, poor insulation design and the use of sub-standard materials results in localized over-heating due to corona type discharges [7].…”
Section: Introductionmentioning
confidence: 99%
“…Polymers, such as ethylene propylene rubber (EPR) [1], ethylene propylene diene methylene (EPDM) [2], silicon rubber [3], paper [4], and thermoset resins, such as phenolic resin (PF) [5], are commonly used for electrical insulation, in addition to glass and ceramic. The polymer electrical insulator is widely used in electronic packaging [6], thermal management [7], high-voltage systems [8], coating [9], distribution lines [10], etc.…”
Section: Introductionmentioning
confidence: 99%
“…Particularly for new power transformers, the technical condition of the electric insulation saturated with dielectric fluids is regarded as the basic hazard to safe operation, where the key factors are the level of moisture as well as the degree of ageing, defined as the degree of the materials' thermal degradation [1][2][3][4][5][6]. Despite decades of designing and manufacturing power transformers, cellulose electric paper saturated with insulating mineral oil continues to be used as the basic electric insulation system.…”
Section: Introductionmentioning
confidence: 99%