Improved in situ Sr isotopic analysis by a 257 nm femtosecond laser in combination with the addition of nitrogen for geological minerals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
47
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 78 publications
(49 citation statements)
references
References 76 publications
1
47
0
Order By: Relevance
“…Neptune or Neptune Plus MC-ICP-MS with either a 193-nm ArF excimer or 257-nm femtosecond laser was employed to measure Sr isotopes at IGGCAS, Beijing and GPMR, Wuhan (Yang et al, 2014(Yang et al, , 2019Zhang et al, 2018Zhang et al, , 2020. A spot size of 60-160 µm was used with a 6-8 Hz repetition rate and an energy density of ∼8 J cm −2 , depending on the Sr content of sample ( Table 1).…”
Section: In Situ Sr Isotopic Analysis By Laser Ablation Mc-icp-msmentioning
confidence: 99%
See 2 more Smart Citations
“…Neptune or Neptune Plus MC-ICP-MS with either a 193-nm ArF excimer or 257-nm femtosecond laser was employed to measure Sr isotopes at IGGCAS, Beijing and GPMR, Wuhan (Yang et al, 2014(Yang et al, , 2019Zhang et al, 2018Zhang et al, , 2020. A spot size of 60-160 µm was used with a 6-8 Hz repetition rate and an energy density of ∼8 J cm −2 , depending on the Sr content of sample ( Table 1).…”
Section: In Situ Sr Isotopic Analysis By Laser Ablation Mc-icp-msmentioning
confidence: 99%
“…Finally, the 87 Sr/ 86 Sr ratios were calculated and normalized from the interference-corrected 86 Sr/ 88 Sr ratio using the exponential law. The whole data reduction procedure was performed using an in-house Excel Visual Basic for Applications (VBA) macro program (Horstwood et al, 2008(Horstwood et al, , 2016Zhang et al, 2018;Zhang et al, 2020).…”
Section: In Situ Sr Isotopic Analysis By Laser Ablation Mc-icp-msmentioning
confidence: 99%
See 1 more Smart Citation
“…The effect was more pronounced for the rat samples, since these incisors had a much lower Sr/Ca (∼3 × 10 −4 , Figure 7) than the guinea pig incisors (up to 8 × 10 −4 , Figure 7) and are thus, due to their lower Sr content, more prone to such interferences. However, we tried to minimize this effect by adding nitrogen to the sample gas flow, as N 2 is known to reduce potential interferences (Zhang et al, 2018), using a desolvator system, and monitored the accuracy of the 87 Sr/ 86 Sr using several matrix-matched tooth samples with known 87 Sr/ 86 Sr (Willmes et al, 2016). By plotting the accuracy of 87 Sr/ 86 Sr vs. 1/ 88 Sr [V] (Supplementary Figure 2), one would expect a strong linear correlation if polyatomic interferences on m/z = 87 ( 40 Ca 31 P 16 O) will affect the 87 Sr/ 86 Sr (Horstwood et al, 2008;Lugli et al, 2017b).…”
Section: Incorporation Of Sr In the Ever-growing Incisor Enamel (Expementioning
confidence: 99%
“…A typical data acquisition cycle consisted of a 30-s measurement of the Kr gas blank with the laser off, followed by 60 s of measurement with the laser on. In this work, YY09-47, YY09-24, and YY12-01 clinopyroxene samples were measured after every 10 unknown samples for external calibration (Yang et al, 2014(Yang et al, , 2019Lin et al, 2016;Zhang et al, 2018Zhang et al, , 2020.…”
Section: In Situ Sr Isotopic Analysis By Laser Ablation Mc-icp-msmentioning
confidence: 99%