2005
DOI: 10.1039/b507647a
|View full text |Cite
|
Sign up to set email alerts
|

Improved in situ isotope analysis of low-Pb materials using LA-MC-ICP-MS with parallel ion counter and Faraday detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
96
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 58 publications
(101 citation statements)
references
References 29 publications
5
96
0
Order By: Relevance
“…15, 2013;Jochum et al, 2005aJochum et al, , 2006 except for GSD-1G, which was doped with selected rare earth elements and transition metals including Pb (48 ppm, Guillong et al, 2005). These reference glasses have been well characterized for Pb isotopes (Elburg et al, 2005;Jochum et al, 2005bJochum et al, , 2011Paul et al, 2005) and therefore, were suitable for validating the analytical method. The selected USGS glasses were all basaltic in composition, whereas the MPI-DING glasses covered a wide range of compositions: basalt (KL2-G), andesite (StHs6/80-G), rhyolite (ATHO-G), quartz-diorite (T1-G), and komatiite (GOR132-G).…”
Section: Samplesmentioning
confidence: 99%
See 2 more Smart Citations
“…15, 2013;Jochum et al, 2005aJochum et al, , 2006 except for GSD-1G, which was doped with selected rare earth elements and transition metals including Pb (48 ppm, Guillong et al, 2005). These reference glasses have been well characterized for Pb isotopes (Elburg et al, 2005;Jochum et al, 2005bJochum et al, , 2011Paul et al, 2005) and therefore, were suitable for validating the analytical method. The selected USGS glasses were all basaltic in composition, whereas the MPI-DING glasses covered a wide range of compositions: basalt (KL2-G), andesite (StHs6/80-G), rhyolite (ATHO-G), quartz-diorite (T1-G), and komatiite (GOR132-G).…”
Section: Samplesmentioning
confidence: 99%
“…Note that a large instrumental mass bias (e.g., Hirata, 1996;Kent, 2008a;Kimura et al, 2013) in the Pb isotopes region was corrected for by the standard bracketing method (Elburg et al, 2005;Paul et al, 2005;Kent, 2008a;Kimura et al, 2013). The remaining interlinearity issue of the MICs can be well compensated in the 10-300 kcps range with the standard bracketing method.…”
Section: Fig 5 Relative Standard Error (Independent In-run 2se%) Vementioning
confidence: 99%
See 1 more Smart Citation
“…Because of these advantages, this technology has quickly been adopted for in situ Pb-isotope analysis. For example, Paul et al 10 using a 93 mm laser spot analyzed the Pb isotopic composition of glass standards. Kent 11 made a comparison between the Faraday cup and ion counting systems for Pb-isotope analysis and argued that the precision is strongly dependent on ion intensities.…”
Section: Introductionmentioning
confidence: 99%
“…Isotopic fractionation corrections were performed using the Exponential Law and NIST SRM610 values from Baker et al (2004) by means of standard-sample bracketing (e.g., Jochum et al 2006;Kent 2008;Paul et al 2005;Simon et al 2007). The fractionation factor was determined using the 208 Pb/ 206 Pb ratio measured in NIST SRM 610.…”
Section: Goals and Samplementioning
confidence: 99%