2019
DOI: 10.1016/j.ijhydene.2019.08.249
|View full text |Cite|
|
Sign up to set email alerts
|

Improved hydrogen storage properties of TiFe alloy by doping (Zr+2V) additive and using mechanical deformation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(4 citation statements)
references
References 73 publications
0
4
0
Order By: Relevance
“…It was clear that the adjustment was better on desorption than adsorption, but the reason for that was not clear at this time. In other reports on TiFe IMC alloys, R 2 values ranged from 0.946 58 to 0.996 59 . Therefore, the adjustment from this study can be considered good.…”
Section: Kinetics Modelling Of the Hydrogenation Of Tife Imc Without Polymer Coveringmentioning
confidence: 71%
See 1 more Smart Citation
“…It was clear that the adjustment was better on desorption than adsorption, but the reason for that was not clear at this time. In other reports on TiFe IMC alloys, R 2 values ranged from 0.946 58 to 0.996 59 . Therefore, the adjustment from this study can be considered good.…”
Section: Kinetics Modelling Of the Hydrogenation Of Tife Imc Without Polymer Coveringmentioning
confidence: 71%
“…It has been previously observed 4 that the absorption kinetics of ball-milled TiFe IMC is also best fitted by the Jander model. In other investigations conducted on TiFe IMC with additives 58,59 , the GB-3D model was best fitted to the data. However, the Jander model was not considered by those authors.…”
Section: Kinetics Modelling Of the Hydrogenation Of Tife Imc Without Polymer Coveringmentioning
confidence: 99%
“…But if we compared the details of the two desorption cycles, it was clear from the first to seventh cycle, the initial kinetic rose with growing cycles but the maximum hydrogen desorption capacity decreased a little. The loss of capacity between the first and seventh absorption was very small, which may be explained by the nature of the apparatus during the measurement process [45]. More cycles for the alloy sample x = 0.6 need to be measured in the future.…”
Section: Cycle Propertiesmentioning
confidence: 99%
“…Recently, the possibility of other activation routes was investigated using severe plastic deformation methods. Mechanical activation of TiFe via HPT [120], groove rolling [122], forging [123] and ball milling [124] were presented. Significant improvement in the room temperature hydrogen absorption was observed after HPT processing [120,122].…”
Section: Non-magnesium-based Materialsmentioning
confidence: 99%