2009
DOI: 10.1177/193229680900300429
|View full text |Cite
|
Sign up to set email alerts
|

Improved Glycemic Control through Continuous Glucose Sensor-Augmented Insulin Pump Therapy: Prospective Results from a Community and Academic Practice Patient Registry

Abstract: Abbreviations: (ANCOVA) analysis of covariance, (AUCH) glucose area >140 mg% normalized to 7 days of the continuous glucose sensor download, (AUCL) glucose area <70 mg% normalized to 7 days of the continuous glucose sensor download, (BAS) basal insulin dose as a percentage of the total daily insulin dose, (BG) weekly mean glucose level, (BOL) number of daily boluses, (CEEGI) Central and Eastern Europe, Greece, and Israel, (CGS) continuous glucose sensing, (DCCT) Diabetes Control and Complications Trial, (GHb) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
23
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(27 citation statements)
references
References 23 publications
4
23
0
Order By: Relevance
“…The results of this pilot study are in accordance with the recent state of the art of development of closed loop systems using CGMS-augmented insulin pumps 9,11,19,20 . Example 1 a) Plasma glucose concentration is 3.5 mmol/L, ie.…”
Section: Discussionsupporting
confidence: 75%
See 2 more Smart Citations
“…The results of this pilot study are in accordance with the recent state of the art of development of closed loop systems using CGMS-augmented insulin pumps 9,11,19,20 . Example 1 a) Plasma glucose concentration is 3.5 mmol/L, ie.…”
Section: Discussionsupporting
confidence: 75%
“…This overcomes the limitations of traditional monitoring by producing glucose profiles instead of distinct measurements, real-time glucose values, glucose trends and warnings when glucose values approach dangerously low or high concentrations. In this way, frequent use of CGM systems and careful pattern analysis can improve glycaemic control [7][8][9][10] . On the other hand, evaluation of the prolific data provided by CGMS often makes the implementation of CGMS in practice, difficult.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering reported data, RT-CGM may possibly be viewed as a behavior-modification tool, and its success is directly dependent on the manner in which it is used. 6 In all the previously mentioned studies there was a positive association between overall sensor use and glycemic profile benefit.…”
Section: Introductionmentioning
confidence: 99%
“…48 Continuous glucose sensing-augmented insulin pump therapy is a further technological advance, whereby sensor-augmented insulin pump therapy integrates real-time CGM with CSII, a technique that has demonstrated improvements in glycemic control in clinical trials and real-world settings. [49][50][51] SMBG versus retrospective CGM Although the CGMS detected significantly more incidences of hypoglycemia and postprandial hyperglycemia compared with standard blood glucose testing, the day-to-day variability was similar between the two groups, and, with a sensor failure rate of 28%, 52 the effectiveness of this method of CGM is debatable.…”
Section: Sensor-augmented Insulin Pump Therapymentioning
confidence: 80%