2019
DOI: 10.1016/j.jvs.2018.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Improved effectiveness of the repositionable GORE EXCLUDER AAA endoprosthesis featuring the C3 delivery system compared with the original GORE EXCLUDER AAA endoprosthesis for within the instructions for use treatment of aortoiliac aneurysms

Abstract: Our study has demonstrated that the repositionable GORE EXCLUDER has important safety characteristics compared with the original device and equivalent long-term effectiveness. Additional benefit was obtained with the use of the Gore Dryseal introducer sheath.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 15 publications
1
6
0
Order By: Relevance
“…Valve delivery and deployment was successful at first pass in all cases. Previous studies have confirmed the 29 mm Edwards SAPIEN XT and SAPIEN 3 valves passed easily through the shorter 33 cm 26Fr Gore Dryseal sheath and bench testing in our cohort had confirmed this was similar in the longer 65 cm sheath. This has also been validated in a recently published communication, although the authors of this report indicated use of the 22Fr delivery system which we found suitable only for the 23 mm diameter valve.…”
Section: Discussionsupporting
confidence: 84%
See 2 more Smart Citations
“…Valve delivery and deployment was successful at first pass in all cases. Previous studies have confirmed the 29 mm Edwards SAPIEN XT and SAPIEN 3 valves passed easily through the shorter 33 cm 26Fr Gore Dryseal sheath and bench testing in our cohort had confirmed this was similar in the longer 65 cm sheath. This has also been validated in a recently published communication, although the authors of this report indicated use of the 22Fr delivery system which we found suitable only for the 23 mm diameter valve.…”
Section: Discussionsupporting
confidence: 84%
“…Therefore, there are clear potential advantages of a longer large bore delivery sheath to facilitate valve delivery, not least the possibility of avoiding the in vivo balloon loading required with the SAPIEN XT and SAPIEN 3. The Dryseal sheath (Gore and Associates, Flagstaff, AZ) is a hydrophilic, flexible kink‐resistant delivery sheath designed primarily for delivery of vascular endografts in the setting of abdominal and thoracic aortic aneurysms . We describe our experience using this sheath to facilitate delivery of the Edwards SAPIEN XT and SAPIEN 3 valves to the dysfunctional RVOT in patients requiring pulmonary valve replacement.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the main assets of the Conformable device is the repositionability featuring the C3 delivery system. A retrospective analysis of 2018 ( 49 ) showed that the repositionable GORE EXCLUDER when used in combination with the C3 delivery system had critical safety properties, including precise placement relative to the renal arteries and equivalent long-term efficacy.…”
Section: Resultsmentioning
confidence: 99%
“…The newly introduced device, Gore Excluder Conformable AAA Endoprosthesis with active control (CEXC) system (W. L. Gore & Associates, Flagstaff, Arizona, USA) has been designed to address these issues. 7 The active control system enables repositioning and adaptability of the device to the native aortic wall, thereby facilitating optimal wall apposition and aggressive infrarenal positioning. This, in turn, maximises the likelihood of achieving seal in complex aortic geometries and avoids early and late type 1aEL.…”
Section: Introductionmentioning
confidence: 99%