2019
DOI: 10.1007/s12350-017-1058-x
|View full text |Cite
|
Sign up to set email alerts
|

Improved diagnosis of the number of stenosed coronary artery vessels by segmentation with scatter and photo-peak window data for attenuation correction in myocardial perfusion SPECT

Abstract: SSPAC-corrected SPECT myocardial perfusion images exhibit improved accuracy in the detection of the number of stenosed coronary artery vessels, even in patients with multi-vessel CAD.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…Five studies used 201 Tl ( 13 , 14 , 28 30 ), 15 studies used 99m Tc, and two studies used dual radiotracers ( 19 , 27 ). Twelve studies used CTAC, seven studies used RAC ( 19 , 27 , 29 , 31 34 ), two studies used AC with segmentation of scatter and photo-peak window data (SSPAC) ( 35 , 36 ), and one study used computer-generated Chang AC ( 30 ). The detailed characteristics of each study are shown in Table 1 ( 13 16 , 19 , 20 , 26 41 ).…”
Section: Resultsmentioning
confidence: 99%
“…Five studies used 201 Tl ( 13 , 14 , 28 30 ), 15 studies used 99m Tc, and two studies used dual radiotracers ( 19 , 27 ). Twelve studies used CTAC, seven studies used RAC ( 19 , 27 , 29 , 31 34 ), two studies used AC with segmentation of scatter and photo-peak window data (SSPAC) ( 35 , 36 ), and one study used computer-generated Chang AC ( 30 ). The detailed characteristics of each study are shown in Table 1 ( 13 16 , 19 , 20 , 26 41 ).…”
Section: Resultsmentioning
confidence: 99%
“…A summary of 16 studies (n=2,092 patients) revealed that the diagnostic sensitivity and specificity of semiconductor SPECT were 84% [95% confidence interval (CI), 78%-89%] and 69% (95% CI, 62%-76%) respectively (4). A comparison of scatter segmentation and photo-peak window data (SSPAC) and non-correction methods for diagnosing individual coronary territories showed that the vessel-based diagnostic ability, sensitivity, specificity, and positive and negative predictive values of the 3-detector SPECT with and without attenuation correction using SSPAC were 77%, 89%, 74%, and 90%, and 51%, 87%, 62%, and 82%, respectively (17). Although diagnostic ability depends on patient selection criteria, the present findings between the modalities were comparable, which supported our conclusions.…”
Section: Accuracy Of Myocardial Perfusion Spect To Detect Coronary Artery Diseasementioning
confidence: 99%
“…Although each of the proposed methods has been successful to somewhat, the attenuation problem is still not fully solved, and therefore, the use of quantitative methods is difficult in SPECT due to attenuation. [6][7][13][14][15][16] In this article, it has been tried to introduce a simple, accurate, and rapid method without imposing more absorption dose to the patient. In this study, it has been tried to use the images of multienergy emitter radioisotope to find an attenuation map.…”
Section: Introductionmentioning
confidence: 99%